YOUR FIRE 

 

UNPACKING, ELECTRICAL INSTALLATION  

& GENERAL SAFETY 

 

GENERAL: 

Unpack  the  fire  carefully  and  retain  the  packaging  for  possible  future  use,  for 
example in the event of moving or returning the fire to your supplier. Remove any 
plastic protection film and transit tape.  
The fire incorporates a flame effect that may be enjoyed at any time of the year; 
using the flame effect on its own only requires minimal electricity.  

 

THIS APPLIANCE MUST BE EARTHED 

 

Check that the voltage shown on the rating label of your fire is the same as your 
dwelling electricity supply which must be AC (alternating current). 
The mains  cord  of  the fire  has  a  UK  type  plug fitted with  a  13amp fuse;  when 
replacing  a fuse  use  a  13amp fuse  approved  to  BS  1362.  The fuse  cover  of  a 
moulded on plug must be refitted after changing the fuse. Should the fuse cover 
become lost, the plug must not be used until the correct replacement fuse cover 
is obtained from your service agent. 
The wires in the mains supply cord are coloured in accordance with the following 
code: Green and Yellow = Earth,   Blue = Neutral,   Brown = Live. 
If  your  fire  is  fitted  with  a  moulded  on  mains  plug  which  is  not  suitable  for  the 
socket outlets in your dwelling, the plug must be cut off and an appropriate one 
fitted.  
Note: A plug cut off from a flexible cord presents a shock hazard if inserted in a 
13  amp  socket  elsewhere  in  the  dwelling,  to  avoid  this  remove  the  fuse  and 
dispose of immediately. 
If  you  are fitting  an  alternative  type  of  plug then  the  colours  of the  wires  in  the 
mains  cord  may  not  correspond  with  the  identifying  markings  on  the  plug 
terminals. In this case proceed as follows: 
The  wire  which  is  coloured  Green/Yellow  must  be connected  to  the terminal  in 
the  plug  which  is  marked  by  the  letter  E  or  by  the  earth  symbol  or  coloured 
Green or Green/Yellow. The wire which is coloured Blue must be connected to 
the terminal in the plug which is marked by the letter N or coloured Black. The 
wire  which  is  coloured  Brown  must  be  connected  to  the  terminal  in  the  plug 
which is marked by the letter L or coloured Red. 

 

Содержание Fuego LE Timer fires

Страница 1: ...xperience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that the...

Страница 2: ...r service agent The wires in the mains supply cord are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live If your fire is fitted with a moulded on mains plug...

Страница 3: ...LIANCE WITHOUT STRETCHING DO NOT USE THIS HEATER WITH AN EXTERNAL PROGRAMME CONTROLLER THERMAL CONTROL TIMER OR ANY OTHER DEVICE WHICH SWITCHES THE HEATER ON AUTOMATICALLY AS A FIRE RISK MAY OCCUR IF...

Страница 4: ...3 Mark fixing holes through hanger bar and drill holes to suit wall fixings and screws 4 Fix hanger bar to wall using suitable fixings 5 The main chassis of the fire is now ready to be fitted 7 Connec...

Страница 5: ...mains connection should be made at the rear of the aperture If the appliance is to be hard wired allow sufficient length of mains cable to enable removal of the appliance from the aperture with the ca...

Страница 6: ...the Facia see below FITTING THE FASCIA The fire front may now be fitted to the fire chassis as follows At the rear of the facia frame there is a large v shaped hook Hook this over the fixing lip loca...

Страница 7: ...ERIES ARE FLAT To operate the fire in manual mode follow the steps below NOTE BY PRESSING FLAME MORE THAN ONCE THERE ARE THREE INTENSITY SETTINGS AVAILABLE NOTE THE DISPLAY INDICATES THE TEMPERATURE O...

Страница 8: ...te your fire in Remote mode follow the steps below 1 When the Mains supply has been turned on the Fire can be activated to Standby mode by pressing the switch on the Fire as shown 2 To switch the Fire...

Страница 9: ...9 OPERATING YOUR FIRE LE TIMER FIRE Not applicable to Manual remote fires To operate the fire follow the steps below NOTE BY PRESSING FLAME MORE THAN ONCE THERE ARE THREE INTENSITY SETTINGS AVAILABLE...

Страница 10: ...n antistatic cloth to prevent dust being attracted to the high gloss surfaces of the fire do not use polish For difficult to remove marks such as finger marks it is rec ommended that a chamois leather...

Страница 11: ...fault is persistent contact your retailer or Imperial Fires Customer Service on the telephone numbers provided at the beginning of these instructions FEATURES MANUAL REMOTE FIRE KEY Standard Option N...

Страница 12: ...ensional Specifications GL Wide GL Standard Height 590mm 575mm Width 720mm 580mm Depth 165mm 165mm Minimum mounting height from floor or surface 60mm Minimum aperture size 535mm High x 440mm Wide GL s...

Страница 13: ...13 NOTES...

Страница 14: ...14 NOTES...

Страница 15: ...you must provide the details requested below otherwise your warranty might be invalid Return this form to your dealer or contact Imperial Fires Limited Imperial Fires Limited reserves the right to re...

Страница 16: ...16 I01427 Fuego Issue C...

Отзывы: