27
26
If you are in Australia and the
following checks do not identify
the fault condition, the equipment
should be returned to a WIA
Service agent. Phone 1300 300 884
for details of your nearest
service agent.
If you are in New Zealand and the
following checks do not identify
the fault condition, the equipment
should be returned to the original
place of purchase with proof of
purchase, or contact Weldwell
on 06 8341 600.
9 EXTERNAL TROUBLE SHOOTING
8 GENERAL MAINTENANCE
Before removing the power
source covers, ENSURE that the
equipment is disconnected from
the mains power supply. When the
equipment is energised LETHAL
VOLTAGES are present on the
electrical components enclosed.
Dust
Care should be taken to prevent excessive
build-up of dust and dirt within the welding
power source. It is recommended that
at regular intervals, according to the
prevailing conditions, the equipment
covers be removed and any accumulated
dust be removed by the use of a dry, low
pressure compressed air, or a vacuum
cleaner. The machine should be blown
out with compressed air at least every 12
months as grinding dust can settle on PCB
componentry causing failure. Failure to
maintain machines may void warranty.