10
6.9
Installing EasiBlades
6.9.1
EasiBlades are supplied as complete single
units. From the 4’ / Gage and midway
between Sleepers / Ties slide the base (W
bracket) over the rail foot as shown. Locate
the hook bolt around the opposite side of
the foot and tighten the single Nyloc nut.
Fully bed the base onto the rail using a
hammer on the vertical faces of the ‘W’
bracket. Retighten the Nyloc nut.
6.9.2
The blades are provided in left and right
hand forms; the difference being the direction the hose tail points, the correct layout is
shown in the adjacent picture, outer pairs with hose tails pointing towards each other.
6.9.3
Tilt the blade up so that the blade tip is towards the rail head and as high as possible,
lightly tighten the two pivot bolts.
6.9.4
Decide the required blade height and tap the steel lugs on the blade down using a hammer
to achieve the required height. The setting gauge described previously should be used to
verify heights.
6.9.5
There may be a slight gap between the tip of the blade and the rail. To close this gap tap
the corner of the lug as necessary, do not hammer the blade itself.
Note: Strike the bracket to angle the blade as shown on the red arrow.
6.9.6
Repeat the process for each EasiBlade.
Содержание EasiPoint
Страница 18: ...18 10Exploded Views of System Elements 10 1 EasiPump Schematic ...
Страница 19: ...19 ...
Страница 20: ...20 ...
Страница 21: ...21 10 2 EasiPoint Schematic ...
Страница 22: ...22 ...
Страница 23: ...23 10 3 Blades ...
Страница 24: ...24 ...
Страница 25: ...25 10 4 Reservoirs ...
Страница 26: ...26 ...
Страница 27: ...27 ...