background image

1. LED does Not
    Blink, Control
    Panel Indicates
    Lube No-Flow

(See also, 3.Erratic shutdown)

D. Bent Magnet Housing

DNFT

A. Improperly Adjusted

NOTICE:  WHEN MORE THAN ONE DNFT IS INSTALLED ON THE COMPRESSOR OR ENGINE, EACH DNFT MUST BE WIRED TO A SEPARATE ALARM

CIRCUIT ON THE CONTROL PANEL, ANNUNCIATOR OR PLC TO SIMPLIFY TROUBLESHOOTING THE LUBRICATION SYSTEM AND DNFT.

B. Spring or Magnet is

Assembly

 Broken in Magnet 

MAGNET

SPACER

SPRING

MAGNET HOUSING (HEX)

STRAIGHT  OK !

BENT   REPLACE !

PISTON

ENCLOSURE

PLUGS

System.

Divider Valve 

B. Air or Debris in

OUTLET PLUGS

ELETRICAL TESTING OF DNFT ALARM CIRCUIT

PROBLEM

POSSIBLE CAUSE

SERVICE PROCEDURE AND / OR CORRECTION

TROUBLESHOOTING DNFT-LED-PS

Remove the battery from the DNFT per the attached instructions.  Replace the 
battery if the voltage is below 2.5 volts using a factory recommended replacement 
battery.

C. Low Battery voltage

CAUTION: DISCONNECT ALL WIRING PRIOR TO WELDING ON COMPRESSOR OR SKID.

DIVIDER VALVE

TYPICAL              INSTALLATION

DNFT

24S

INTERNAL VIEW OF 

DIVIDER VALVE

PISTON ENCLOSURE PLUG

O-RING OR

METAL GASKET

24S

 Faulty Lube Pump

Loosen set screws, remove DNFT from magnet housing. Check for damaged or 
bent magnet housing.   Remove magnet assembly from divider valve.   Replace 
magnet housing, magnet, spring and spacer.  Re-install DNFT on magnet 
housing.   If necessary, adjust DNFT, check for LED blink.   Purge air from 
system 

with lubrication system purge gun.

1. 

NORMALLY  OPEN

 - Attach ohmmeter to red wires. Meter should read 10 

megaohms in operation and less than 10 ohms in alarm state.
2. 

NORMALLY  CLOSED

 - Attach ohmmeter to orange wires. Meter should  

read less than 10 ohms in operation and infinity in alarm state. 

Loosen set screws and remove DNFT from magnet housing. Check for correct 
magnet housing for divider valve manufacturer. Remove and replace with correct 
magnet housing. Replace DNFT on magnet housing. If necessary adjust DNFT, 
check for LED blink. Purge air from system with lubrication system purge gun.  

Check system pressure insure oil is flowing to divider valves.  If necessary 
install pressure gauge to monitor operation of lubrication system.
1. Loosen outlet plugs in front of valve blocks. Fast purge the system with 
lubrication system purge gun until clean, clear, air free oil appears from  plugs.
2. Loosen each piston enclosure plug   individually to purge air from behind 
piston. Do not remove piston enclosure plugs. Tighten all divider valve plugs. 
Adjust DNFT.   

To insure proper operation of the divider block lubrication 

system, it is absolutely necessary that all tubing and components be filled 
with oil and free of air before start-up.

Check system pressure to insure oil is flowing to divider valves.   If necessary, 
install pressure gauge to monitor operation of lubrication system.  Check gauge 
to insure pump will build sufficient pressure to inject oil into cylinder.  You cannot 
check for oil flow into cylinder by removing tubing from check valve and pumping 
oil to atmosphere.   Replace pump.

Loosen set screws, remove DNFT from magnet housing.  Remove magnet 
assembly from divider valve. Remove magnet, spacer and spring. Check 
components for damage.  Replace damaged spring and/or magnet and install on 
divider valve. If necessary, adjust DNFT, check for LED blink.   Purge air from 
system with lubrication system purge gun.

Loosen set screws, slide DNFT all the way onto hex of magnet housing and 
torque to 25 inch pounds max.(

Do not over tighten)

 Cycle divider valve by 

pumping clean oil through system with lubrication system purge gun or running 
compressor. If necessary, adjust DNFT 1/16“ back until LED blinks  with each 
cycle of divider valve.

2. After installation of 
DNFT, Rupture Disc is 
Blown and Divider Valve 
is Locked up.

A.Wrong Magnet Housing.
Installed on Divider Valve 
(See magnet assy. Below)  

RED
RED
ORANGE
ORANGE
GREEN
YELLOW

507LIT LED-PS-WI-3

06.05.01

U.S. PAT. NO. 5,835,372

R

DIGITAL NO-FLOW TIMER

DNFT

ODESSA, TX USA

INSTRUMENT

INSTRUMENT

WHITLOCK 

WHITLOCK 

1-800-337-34121-800-337-3412

www

.noflo.com

www

.noflo.com

DNFT-LED-PS

DIGITAL NO-FLOW TIMER

R

3 - M I N

2.5VA / 240VDC 

2.5VA / 240VDC 

LED-PS

LED-PS

U.S. PAT. NO. 5,835,372

RED-Open Loop   ORANGE-Closed Loop    GRN-Ground    YEL -Prox. SWI.

MODEL

RATED

SERIAL #

PN

ALARM

186200

CE

R

US

Cl I; Div 1; Grps. A,B,C,D;T4

Cl I; Zone 1; Ex md IIC T4

Factory Sealed

CYCLE INDICATION

          0344

KEMA 00ATEX1090 X Amb. -40° C...+80°C

         II 2G EEx m IIC T5

0 0 0 5 0 7

0 0 0 5 0 7

ODESSA, TX USA

INSTRUMENT

INSTRUMENT

WHITLOCK 

WHITLOCK 

1-800-337-34121-800-337-3412

www

.noflo.com

www

.noflo.com

WHITLOCK INSTRUMENT

1300 N. Texas

Odessa, TX 79761

432.3373412 Fax 432.335.5926

1.800.337.3412       www.noflo.com

DNFT must be installed with correct magnet

assembly for each divider valve manufacturer.

Magnet Assemblies and Applications

Trabon Metal Gasket Seal
1994 or Earlier
7/16"-20

Lincoln O-Ring Seal
Extended Nose
7/16"-20

SBCO &TRABON
O-Ring Seal
7/16"-20

Dropsa No Gasket
Raised Shoulder

Magnet Assy # 000011

Magnet Assy # 000012

Magnet Assy # 000004

Magnet Assy # 000013

Содержание DNFT-LED-PS

Страница 1: ...ocessor and transistor components for detecting Slow Flow and No Flow of divider block lubrication systems The DNFT incorporates an oscillating crystal to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability The magnet assembly and control housing mount directly to the divider valve to become an integral part of the lubrication system The DNFT o...

Страница 2: ...O ring or metal gasket F is in place on magnet housing C Screw magnet housing C into end of divider valve E Torque to 15 foot pounds max 4 Slide DNFT B all the way onto hex of magnet housing C Tighten set screws on hex of magnet housing Torque 25 inch pounds max 5 The LED on the DNFT indicates each divider valve cycle This enables operator to adjust the lubricator pump for correct cycle time and o...

Страница 3: ...ure plugs Tighten all divider valve plugs Adjust DNFT To insure proper operation of the divider block lubrication system it is absolutely necessary that all tubing and components be filled with oil and free of air before start up Check system pressure to insure oil is flowing to divider valves If necessary install pressure gauge to monitor operation of lubrication system Check gauge to insure pump...

Страница 4: ...tact DNFT BATTERY REPLACEMENT INSTRUCTIONS Directions for replacing the battery in the Digital No Flow Timer MAGNET H POLARIZED CONNECTOR CONTROL HOUSING B SPRING SPACER LED 22 AWG 18 LEADS 7 I O RING F 1 2 PIPE PLUG FIELD REPLACEABLE BATTERY P N 000505 MAGNET HOUSING C ALLEN HEAD SET SCREWS 2 A RED RED GREEN ORANGE ORANGE YELLOW 507LIT LED PS WI 4 06 05 01 R DIGITAL NO FLOW TIMER U S PAT NO 5 835...

Отзывы: