Settlement of outdoor unit
Anchor the outdoor unit tightly and
horizontally on a concrete or rigid
mount with a bolt and nut 10 or 8
diameter.
Drain joint installation
Fit the seal into the drain elbow, then insert the
drain joint into the base pan hole of outdoor
unit, rotate 90 to securely assemble them.
Connecting the drain joint with an extension
drain hose (Locally purchased), in case of the
water draining off the outdoor unit during the
heating mode.
Air inlet
Air
inlet
Air outlet
A
B
Flaring work
Main cause for refrigerant leakage is
due to defect in the flaring work.
Carry out correct flaring work using the
following procedure:
1. Cut the pipes and the cable.
A) Use the piping kit accessory or
pipes purchased locally.
B) Measure the distance between the
indoor and the outdoor unit.
C) Cut the pipes a little longer than the
measured distance.
D) Cut the cable 1.5m longer than the
pipe length.
2. Burr removal
A) Completely remove all burrs from
the cut cross section of pipe/tube.
B) Put the end of the copper.
tube/pipe in a downward direction
as you remove burrs in order to
avoid dropping burrs into the
tubing.
3. Putting nut on.
A) Remove flare nuts attached to
indoor and outdoor unit, then put
them on pipe/tube having
completed burr removal.(not
possible to put them on after flaring
work)
Refrigerant piping connection
17
Outdoor unit installation
18
Refrigerant piping connection
Base pan hole
of outdoor unit
Seal
Drain joint
Seal
Drain pipe
+
=
Pipe
Correct
Wrong
Oblique Roughness Burr
Pipe
Reamer
Point
down
Flare nut
Cooper tube
Dimension of the external
unit / mm - (AnxAlxP)
Mounting dimensions
A(mm)
B(mm)
24k Btu models
700x540x240
685x430x260
780x540x250
760x590x285
845x700x320
775x545x310
670x540x250
760x590x285
820x590x330
845x700x320
458
460
549
530
560
600
481
530
526
560
250
276
276
290
335
320
276
290
340
335