WIRING DIAGRAM 3

 – 

Heat Pump Thermostats 

 

C  

O/B

R  Y  G  E

E
G
Y
R
W/O/B
C
CLOSE
OPEN
COM

ZONE 

CONNECTIONS

T

HE
RM

O

S

T

A

T

   

  

  

 DA

M

P

E


  

Heat Pump Thermostat

 

 
 
 
 
 
WIRING DIAGRAM 4 –  

Typical Heat Pump Equipment 

 

Compressor Relay

Reversing Valve

24V. Transformer

Second Stage Heat Relay

Emergency Heat Relay

Fan Relay

EQ

U

IP

M

EN

T

AIR TO AIR HEAT PUMP  CONNECTIONS

HEAT PUMP CONTROLS

W2

W1

Y1
Y2

O

G

E

B

R

W3

Compressor Relay

Reversing Valve

24V. Transformer

Second Stage Heat Relay

Emergency Heat Relay

Fan Relay

EQ

U

IP

M

EN

T

AIR TO AIR HEAT PUMP  CONNECTIONS

HEAT PUMP CONTROLS

W2

W1

Y1
Y2

O

G

E

B

R

W3

 

 
 
 
 
 
 
 
 
 
 
 
 

 
TROUBLESHOOTING 

The CZ-4  is a very simple control to troubleshoot, especially with the 
LED indicators.  The only other device needed is a simple Volt/Ohm 
meter.  Almost all problems can be traded to an external component 
or wiring to the CZ-4.   While the CZ-4 has been designed to operate  
 
under extreme voltage conditions and is fuse protected, like any 
computer the micro-processor can hang up and not operate properly.  
For these instances a BOOT button has been installed that re-boots 
the micro-processor just like your computer.  Pressing this button for 
a few seconds and then release it will allow the micro-processor to re-
boot and in most all cases eliminate the problem.  If not the following 
procedure can help isolate the problem.   
 

 

Zone(s) Not Calling 

Each zone has a Green LED next to the zone relay when it is calling 
and that calling is being recognized by the CZ-4.  If a zone is 
supposed to be calling and the Zone LED is not on, check for 24VAC 
across the thermostat terminal C and the Y, if a Cool call, W if a Heat 
Call, or G if a Fan call.  If there is no voltage here at the panel the 
panel is not getting the signal from the thermostat.  The problem is 
mis-wiring, a broken wire or a problem in the thermostat.  To check 
the zone on the panel, place jumper from R to Y, R to W or R to G to 
see that the panel is operating properly.   

 
Zone(s) Will Not Shut Off 

If a zone will not stop calling, the Zone LED should still be on.  
Depending on the call  disconnect the Y, W or G wire from the 
terminal strip.  The zone will drop out.  Check the thermostat wiring 
for a mis-wiring or short that keeps the zone calling.    
 

Damper Motor Checkout 

Each zone has Green  indicator  light  located to the right of the zone 
damper’s  relay.    When all zones are satisfied  all zone LEDs  are lit 
Green indicating all zone dampers will be Open.  To check this there 
will be 24VAC across the COM and Open terminal.  When any zone 
calls, the damper(s) to the satisfied zone(s) will power close and the 
indicator light will go out.  When the damper is to be closed there will 
be 24VAC across COM and CLOSE.   
 
 
      

              

 

 

St. Louis, MO.  Markham, Ontario 

www.white-rodgers.com 

 
 
 

 
 

 
 
 

BOOT 

Содержание CZ-4

Страница 1: ...FORM 2045 2 1306 2013 White Rodgers by Permission 37 6864B Model CZ 4 Installation and Operating Instructions ...

Страница 2: ...e by pulling firmly and separating the cover from the case exposing the circuit board There are 4 key hole mounting points in each corner of the case The case has openings in the rear of the case as well as the side for all wiring Wiring can come from the back as well as the side in order to make a neat installation OPERATION The CZ 4 can control various types of HVAC Equipment all from the same p...

Страница 3: ...3 O TO W Switch is placed to ON when using Heat Pump thermostats that use an O terminal to activate the reversing valve in COOLING The O on the thermostat is wired to W on the zone terminal in order to determine if the call is for heating or cooling All zone thermostats must operate and be wired the same way 4 B TO W Switch is used when using Heat Pump thermostats that use a B terminal to activate...

Страница 4: ...time the unit has already been supplying the first mode in order to determine how long it will hold off the opposite call If an opposite call is made shortly after the first call the opposite call may be held off for as much as 20 minutes If the first call or subsequent calls for the first call mode has had that mode operating for up to 20 minutes already and an opposite call comes in after 20 min...

Страница 5: ... all cases eliminate the problem If not the following procedure can help isolate the problem Zone s Not Calling Each zone has a Green LED next to the zone relay when it is calling and that calling is being recognized by the CZ 4 If a zone is supposed to be calling and the Zone LED is not on check for 24VAC across the thermostat terminal C and the Y if a Cool call W if a Heat Call or G if a Fan cal...

Страница 6: ... G Y R W O B C CLOSE OPEN COM ZONE CONNECTIONS THERMOSTAT DAMPER Single Stage Thermostat ON OFF HEAT PUMP EQUIP FAN ON IN HEAT STAT O TO W STAT B TO W FAN IN PURGE EMERGENCY HEAT STAGE TIME ZONE CTRL 3 1 2 3 4 5 6 7 8 W2 W1 Y1 Y2 O G E B R First Stage Cooling Relay 24V Transformer Second Stage Cooling Relay First Stage Heat Relay Fan Relay EQUIPMENT HEATING COOLING EQUIPMENT Second Stage Heat Rela...

Отзывы: