White Rodgers 1F97-0671 Скачать руководство пользователя страница 8

8

OPERATING YOUR THERMOSTAT

If at any time during testing your system does not operate 
properly, contact a qualifi ed service person.

Fan Operation

If your system does not have a G terminal connection, skip to 

Heating System.

1.  Turn on power to system.
2.  Press FAN button to select 

ON

. The blower should begin     

    to operate.
3.  Press FAN button to select 

AUTO

. The blower should 

 stop 

immediately.

To prevent static discharge problems, touch side of 
thermostat to release static build-up before touching 
any keys.

NOTE

Check Thermostat  Operation

Do not allow the compressor to run unless the com-
pressor oil heaters have been operational for 6 hours 
and the system has not been operational for at least 
5 minutes.

CAUTION

!

Heating System

1. Press SYSTEM button to select 

Heat

. If the auxiliary   

heating system has a standing pilot, be sure to light it.

2. Press 

 to adjust thermostat setting to 1° above room 

temperature. The heat pump system should begin to oper-
ate. The display should show 

“System On”

 (see Confi gu-

ration menu, item 11).

3. Press 

 to adjust the thermostat below room tempera-

ture. The heating system should stop operating.

To prevent compressor and/or property damage, if the 
outdoor temperature is below 50°F, DO NOT operate 
the cooling system.

CAUTION

!

Cooling System

1.  Press SYSTEM button to select 

Cool.

2. Press 

 to adjust thermostat setting below room tem-

perature. The blower should come on immediately on high 
speed, followed by cold air circulation. The display should 
show 

“System On”

. If the setpoint temperature display is 

fl ashing, the compressor lockout feature is operating  (see 
Confi guration menu, item 5).

3. Press 

 to adjust the temperature setting above room

temperature. The cooling system should stop operating.

Choose the Fan Setting (Auto or On)

Fan 

Auto

 is the most commonly selected setting and runs the 

fan only when the heating or cooling system is on.
Fan 

On

 selection runs the fan continuously for increased air 

circulation or to allow additional air cleaning.
Fan 

Prog

 

On 

indicates that the fan is programmed to be on 

for the entire period. The 

Prog Fan On

 can be overridden 

to have the fan cycle with the system. Press the FAN but-
ton to change the fan to Auto. The fan programming will be 
overridden until the next program period begins or until 

Run 

Schedule

 is pressed.

Choose the System Setting
(Cool, Off, Heat, Auto)

Press the SYSTEM button to select:

Heat: 

Thermostat controls only the heating system.

Off: 

Heating and Cooling systems are off.

Cool: 

Thermostat controls only the cooling system.

Auto: 

Auto Changeover is used in areas where both heating 

and cooling may be required on the same day. 

AUTO

 allows 

the thermostat to automatically select heating or cooling 
depending on the indoor temperature and the selected heat 
and cool temperatures. When using 

AUTO

, be sure to set the 

Cooling temperatures more than 1° Fahrenheit higher than 
the heating temperature.

Manual Operation for
Non-Programmable Mode

Press the SYSTEM button to select 

Heat

 or 

Cool

 and use

the buttons to adjust the temperature to your desired setting. 
After selecting your desired settings you can also press the 
SYSTEM button to select 

AUTO

 to allow the thermostat to 

automatically change between 

Heat

 and 

Cool

.

Manual Operation (Bypassing the Program)
Programmable Mode

Adjust the temperature wherever you like and then press 
the 

HOLD

 button. This will override the program. The 

HOLD

 

feature bypasses the program and allows you to adjust the 
temperature manually, as needed. Whatever temperature 
you set in 

HOLD

 will be maintained 24 hours a day, until you 

manually change the temperature or press 

Run Schedule

 to 

cancel 

HOLD

 and resume the programmed schedule.

Program Override (Temporary Override)

Press buttons to adjust the temperature. This will override the 
temperature setting for a two hour override period. 

Example: 

If you turn up the heat during the morning program, 

it will be automatically lowered later, when the temporary hold 
period ends. To cancel the temporary setting at any time and 
return to the program, press 

Run Schedule

.

If the SYSTEM button is pressed to select 

AUTO

 the

thermostat will change to Heat or Cool, whichever ran last. If
it switches to heat, but you want cool, or it changes to cool, 
but you want heat, press both buttons simultaneously to 
change to the other mode.

Содержание 1F97-0671

Страница 1: ...ture Sensor Indoor or Outdoor Yes ATTENTION MERCURY NOTICE This product does not contain mercury However this prod uct may replace a product that contains mercury Mercury and products containing mercu...

Страница 2: ...ng Power Stealing Switches The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch op...

Страница 3: ...system wiring information This thermostat is designed to operate a single transformer or two transformer system This thermostat is configured for use with the following fossil fuel systems SINGLE STAG...

Страница 4: ...u 8 Displays Save when Cool SavingsTM is working 9 Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non programmable mode 10 Initially displays Auto Sched If Auto Schedu...

Страница 5: ...MENU 0 current temperature 1 HI 2 HI 3HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 10 MENU F C Selects Fahrenheit Celsius Temperature Display 11 MENU On b OFF May select Beeper O...

Страница 6: ...E To change cycle rate press the or button Cycle rate differentials for different settings are MODE Fast Medium Slow FA ME SL Heat SS1 MS2 0 4 F 0 6 F 1 7 F Cool SS1 MS2 0 9 F 1 2 F 1 7 F 6 Select Com...

Страница 7: ...tton to advance Return to this point when you are ready to start your selected lock out and continue by Press Display will read 001 Pressing or buttons to select your keypad lock out combination numbe...

Страница 8: ...ntire period The Prog Fan On can be overridden to have the fan cycle with the system Press the FAN but ton to change the fan to Auto The fan programming will be overridden until the next program perio...

Страница 9: ...day and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 7 day schedule fil...

Страница 10: ...and repeat steps 2 through 5 7 Press RunSched to return to normal operation Fill in the blank schedule on the previous page then Enter the Heating Program 1 Press SYSTEM button to select Heat in the s...

Страница 11: ...perature will be Remote for indoor sensor or Outdoor Remote for outdoor sensor If the remote sensor is an indoor sensor and the local display has been disabled the temperature displayed as the room te...

Страница 12: ...the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting...

Отзывы: