White Rodgers 1F97-0671 Скачать руководство пользователя страница 5

5

INSTALLER/CONFIGURATION MENU

Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-
vance to the next menu item. Press 

 or 

 to change a menu item options. 

INSTALLER/CONFIGURATION MENU

MENU

REF.

PRESS

BUTTON

DISPLAYED 

(FACTORY DE-

FAULT)

Press 

 or 

 to

select from listed op-

tions

COMMENTS

1

MENU

(GAS)

ELE

GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower

2

MENU

CS (3)

0, 1, 2, 4, 5, 6

Selects Cool Savings

Value 1 (low) to 6 (high), 

Value 0 disables feature

3

MENU

E (On)

OFF

Selects Energy Management Recovery (EMR)

On or OFF. 

4

MENU

CR Heat (ME)

SL, FA

Adjustable Anticipation:

Selects heating cycle rate for MS or SS in #1 only

5

MENU

CR Cool (ME)

SL, FA

Adjustable Anticipation:

Selects the cycle rate for cooling

6

MENU

CL (OFF)

CL On

Compressor Lockout Time

7

MENU

 Cool Off, Heat Auto

Heat Auto Cool Off,

Heat Off with Fan icon,

Heat Off without Fan icon

Cool Off, Auto Off

System Mode Confi guration

with Automatic Changeover capability

8

MENU

dL (On)

dL OFF

Selects Display Light On or OFF

9

MENU

0

(current temperature)

1 HI, 2 HI, 3HI, 4 HI,

1 LO, 2 LO, 3 LO, 4 LO

Adjustable Ambient Temperature Display

10

MENU

°F

°C

Selects Fahrenheit/Celsius Temperature Display

11

MENU

(On) b

OFF

May select Beeper OFF to stop audible 

key feedback               

12

MENU

P (7)

3, 0

Defaults 7-day programming (P7) but non-

programmable (0) or 5/1/1 programming (P3)

is available on most models. 

13

MENU

PS (4)

2

Selects Program periods per day: 

4 = Morn, Day, Eve, Night

2 = Day, Night

14

MENU

Heat AS (On)

OFF

Automatic Schedule for heat mode 

15

MENU

Cool AS (On)

OFF

Automatic Schedule for cool mode

16

MENU

Remote (OFF)

On

Selects Remote Sensor On/OFF

MENU

Remote

(In)

Outdoor

Selects Remote Sensor to outdoor

NA is Remote Sensor OFF

MENU

Indoor Loc 

(On)

OFF

Selects Local Sensor (in thermostat) to OFF. 

N/A if Remote is selected to Outdoor

17

MENU

dS (On)

Off

Selects Automatic Daylight Saving Time option

18

MENU

(OFF)

Keypad Lockout

L, P, Limit

Selects one of 3 Keypad Lockout confi gurations

L - Total Keypad Lockout

P - Partial Keypad Lockout 

(Up and Keys still work)

Limit - Limited Temperature RANGE

MENU

(000)

Keypad Lockout

1-999

Selects personal lockout code. 000 is NOT A 

VALID CODE.

19

MENU

L Heat

(99)

L 62 to L 98

Selects Limited HEAT Range Temperature

20

MENU

L Cool

(45)

L 46 to  L 82

Selects Limited COOL Range Temperature

Содержание 1F97-0671

Страница 1: ...ture Sensor Indoor or Outdoor Yes ATTENTION MERCURY NOTICE This product does not contain mercury However this prod uct may replace a product that contains mercury Mercury and products containing mercu...

Страница 2: ...ng Power Stealing Switches The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch op...

Страница 3: ...system wiring information This thermostat is designed to operate a single transformer or two transformer system This thermostat is configured for use with the following fossil fuel systems SINGLE STAG...

Страница 4: ...u 8 Displays Save when Cool SavingsTM is working 9 Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non programmable mode 10 Initially displays Auto Sched If Auto Schedu...

Страница 5: ...MENU 0 current temperature 1 HI 2 HI 3HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 10 MENU F C Selects Fahrenheit Celsius Temperature Display 11 MENU On b OFF May select Beeper O...

Страница 6: ...E To change cycle rate press the or button Cycle rate differentials for different settings are MODE Fast Medium Slow FA ME SL Heat SS1 MS2 0 4 F 0 6 F 1 7 F Cool SS1 MS2 0 9 F 1 2 F 1 7 F 6 Select Com...

Страница 7: ...tton to advance Return to this point when you are ready to start your selected lock out and continue by Press Display will read 001 Pressing or buttons to select your keypad lock out combination numbe...

Страница 8: ...ntire period The Prog Fan On can be overridden to have the fan cycle with the system Press the FAN but ton to change the fan to Auto The fan programming will be overridden until the next program perio...

Страница 9: ...day and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 7 day schedule fil...

Страница 10: ...and repeat steps 2 through 5 7 Press RunSched to return to normal operation Fill in the blank schedule on the previous page then Enter the Heating Program 1 Press SYSTEM button to select Heat in the s...

Страница 11: ...perature will be Remote for indoor sensor or Outdoor Remote for outdoor sensor If the remote sensor is an indoor sensor and the local display has been disabled the temperature displayed as the room te...

Страница 12: ...the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting...

Отзывы: