White Rodgers 1F97-0671 Скачать руководство пользователя страница 4

4

Programming and Confi guration Items 

1

 

"System On"

 indicates when heating or cooling stage

 is 

energized. 

2

 

The word 

"Hold"

 is displayed when the thermostat is

 in 

the 

Hold

 mode. 

"Temp" 

is displayed when

 

the thermostat is in a 

Temporary HOLD

 mode.

3  

Displays 

"Change Filter" 

when the system has run for

 the 

programmed 

fi lter time period as a reminder to

 

change or clean your fi lter.

4

 Displays 

"Set" 

for setpoint when in Run Program mode.

5

 

Displays System Mode 

(Heat, Auto, Cool, Off)

 

 or 

"Time"

 in menu mode.

6

 

Displays 

Fan 

mode

 (On, Auto) "Prog FAN On"

 or    

 

"Run Sched"

 in 

Menu 

mode.

THERMOSTAT QUICK REFERENCE

Home Screen Description

Figure 5 – Home Screen Display

Figure 6 – Programming & Confi guration Items

7

 

Displays 

"Run Schedule"

"Schedule"

, or 

"Menu"

.

8

 

Displays 

"Save" 

when 

Cool Savings

TM

 is working.

9

 

Displays 

"Hold"

 in programmable mode when not in

 

Hold 

mode. Displays 

Light Bulb

 in non-programmable  

 mode. 

10

 

Initially displays 

"Auto Sched". 

If Auto Schedule had

 

been used or disabled, then it displays 

"Cool Savings"

 

when in the Cool Mode. Displays 

"Copy"

 in Schedule  

 mode 

and 

"Fan"

 in Fan Schedule mode.

11

  

"Call For Service"

 indicates a diagnostic fault in the   

 

heating/cooling system, it does not indicate a fault in the

 thermostat.

12

  

"Keypad Lockout" 

in Menu mode when selecting key- 

 

pad Lockout or in RUN when a keypad Lockout is active.

Room

Temperature

Setting
Temperature

System

Indicator

Fan
Indicator

Displays the power level of
the 2 “AA” batteries:
 

    indicates good power level

 

    indicates batteries at about

half power. “

Change          

” indicates

batteries are low and should be 
replaced with 2 new premium brand 
“AA” Alkaline batteries. 
(See page 2 for more details)

10

9

7

6

5

12

1

3

11

8

2

4

Содержание 1F97-0671

Страница 1: ...ture Sensor Indoor or Outdoor Yes ATTENTION MERCURY NOTICE This product does not contain mercury However this prod uct may replace a product that contains mercury Mercury and products containing mercu...

Страница 2: ...ng Power Stealing Switches The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch op...

Страница 3: ...system wiring information This thermostat is designed to operate a single transformer or two transformer system This thermostat is configured for use with the following fossil fuel systems SINGLE STAG...

Страница 4: ...u 8 Displays Save when Cool SavingsTM is working 9 Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non programmable mode 10 Initially displays Auto Sched If Auto Schedu...

Страница 5: ...MENU 0 current temperature 1 HI 2 HI 3HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 10 MENU F C Selects Fahrenheit Celsius Temperature Display 11 MENU On b OFF May select Beeper O...

Страница 6: ...E To change cycle rate press the or button Cycle rate differentials for different settings are MODE Fast Medium Slow FA ME SL Heat SS1 MS2 0 4 F 0 6 F 1 7 F Cool SS1 MS2 0 9 F 1 2 F 1 7 F 6 Select Com...

Страница 7: ...tton to advance Return to this point when you are ready to start your selected lock out and continue by Press Display will read 001 Pressing or buttons to select your keypad lock out combination numbe...

Страница 8: ...ntire period The Prog Fan On can be overridden to have the fan cycle with the system Press the FAN but ton to change the fan to Auto The fan programming will be overridden until the next program perio...

Страница 9: ...day and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 7 day schedule fil...

Страница 10: ...and repeat steps 2 through 5 7 Press RunSched to return to normal operation Fill in the blank schedule on the previous page then Enter the Heating Program 1 Press SYSTEM button to select Heat in the s...

Страница 11: ...perature will be Remote for indoor sensor or Outdoor Remote for outdoor sensor If the remote sensor is an indoor sensor and the local display has been disabled the temperature displayed as the room te...

Страница 12: ...the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting...

Отзывы: