Blue Residential Thermostat 

with Automatic Heat/Cool 

Changeover Option

Model

Programming Choices

1F97-0671

7 Day

5/1/1 Day

Non-Programmable

www.white-rodgers.com

PART NO. 37-6975A

0832

For Single Stage Applications

Installation and Operating Instructions for Model:

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

1F97-0671 Residential Thermostat

SPECIFICATIONS

To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.

CAUTION

!

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS 
CAREFULLY BEFORE INSTALLING OR OPERATING THIS 
CONTROL COULD CAUSE PERSONAL INJURY AND/OR 
PROPERTY DAMAGE.

Description

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Wired Remote Temperature Sensor (Indoor or Outdoor)

Yes

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.

Mercury and products containing mercury must not be 
discarded in household trash. Do not touch any spilled 
mercury. Wearing non-absorbent gloves, clean up any 
spilled mercury and place in a sealed container. For proper 
disposal of a product containing mercury or a sealed 
container of spilled mercury, place it in a suitable shipping 
container. Refer to

 www.white-rodgers.com

 for location to 

send product containing mercury.

Index

Page

Installation

2

Wiring Connections

3

Wiring Diagrams

3

Thermostat Quick Reference

4

Installer Confi guration Menu

5

Operating Your Thermostat

8

Programming

9

Troubleshooting

12

Electrical Rating:
 

Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . .    mV to 30 VAC, NEC Class II, 50/60 Hz or DC

 

Input-Hardwire  . . . . . . . . . . . . . . . . . . . . . . . . .    20 to 30 VAC

Terminal Load  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    1.5A per terminal, 2.5A maximum all terminals combined
Setpoint Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . .    45 to 99°F (7 to 32°C)
Differential (Single Stage)  . . . . . . . . . . . . . . . . . . . .    Heat 0.6°F; Cool 1.2°F
Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . .    32°F to +105°F (0 to +41°C)
Operating Humidity  . . . . . . . . . . . . . . . . . . . . . . . . .    90% non-condensing max.
Shipping Temperature Range  . . . . . . . . . . . . . . . . .    -40 to +150°F (-40 to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . .    4.2"H x 6.4"W x 1.7"D

Содержание 1F97-0671

Страница 1: ...ture Sensor Indoor or Outdoor Yes ATTENTION MERCURY NOTICE This product does not contain mercury However this prod uct may replace a product that contains mercury Mercury and products containing mercu...

Страница 2: ...ng Power Stealing Switches The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch op...

Страница 3: ...system wiring information This thermostat is designed to operate a single transformer or two transformer system This thermostat is configured for use with the following fossil fuel systems SINGLE STAG...

Страница 4: ...u 8 Displays Save when Cool SavingsTM is working 9 Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non programmable mode 10 Initially displays Auto Sched If Auto Schedu...

Страница 5: ...MENU 0 current temperature 1 HI 2 HI 3HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 10 MENU F C Selects Fahrenheit Celsius Temperature Display 11 MENU On b OFF May select Beeper O...

Страница 6: ...E To change cycle rate press the or button Cycle rate differentials for different settings are MODE Fast Medium Slow FA ME SL Heat SS1 MS2 0 4 F 0 6 F 1 7 F Cool SS1 MS2 0 9 F 1 2 F 1 7 F 6 Select Com...

Страница 7: ...tton to advance Return to this point when you are ready to start your selected lock out and continue by Press Display will read 001 Pressing or buttons to select your keypad lock out combination numbe...

Страница 8: ...ntire period The Prog Fan On can be overridden to have the fan cycle with the system Press the FAN but ton to change the fan to Auto The fan programming will be overridden until the next program perio...

Страница 9: ...day and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 7 day schedule fil...

Страница 10: ...and repeat steps 2 through 5 7 Press RunSched to return to normal operation Fill in the blank schedule on the previous page then Enter the Heating Program 1 Press SYSTEM button to select Heat in the s...

Страница 11: ...perature will be Remote for indoor sensor or Outdoor Remote for outdoor sensor If the remote sensor is an indoor sensor and the local display has been disabled the temperature displayed as the room te...

Страница 12: ...the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting...

Отзывы: