Cooling System

1.  Move SYSTEM switch to 

COOL 

position.

2.  Press 

  to  adjust  thermostat  setting  below  room 

temperature. The blower should come on immediately on 
high speed, followed by cold air circulation. However, if the 
setpoint  temperature  is  flashing,  the  compressor  lockout 
feature is operating (see Configuration menu, item 6).

To prevent compressor and/or property damage, if the 
outdoor  temperature  is  below  50

o

F,  DO  NOT  operate 

the cooling system.

CAUTION

!

Do  not  allow  the  compressor  to  run  unless  the 
compressor  oil  heaters  have  been  operational  for  6 
hours and the system has not been operational for at 
least 5 minutes.

CAUTION

!

lockout feature is already present in their system. When the 
thermostat compressor time delay occurs, it will flash the 
setpoint for up to five minutes.

7)  Select Backlight Display

 - The display backlight improves 

display  contrast  in  low  lighting  conditions.  When  the  “C” 
terminal is connected, selecting backlight CdL On will keep 
the light on continuously. Select backlight OFF will turn the 
light on momentarily when any key is pressed. When the 
“C” terminal is not connected, regardless of the backlight 
selection, the light will be on momentarily when any key is 
pressed.

8)  Select Temperature Display Adjustment 4 LO to 4 HI

 - 

Allows you to adjust the room temperature display up to 4° 
higher or lower. Your thermostat was accurately calibrated 
at the factory but you have the option to change the display 
temperature  to  match  your  previous  thermostat.  The 
current or adjusted room temperature will be displayed on 
the display.

INSTALLER/CONFIGURATION MENU 

9)  Select F° or C° Readout

 - Changes the display readout to 

Celsius or Fahrenheit as required.

10)

 

Select  Filter  Replacement  Reminder  and  Set  Run Time 

Select the 

“Change Filter”

 reminder On or OFF. If selected 

On, press RUN/HOLD to select the time period from 25 to 
1975 hours in 25 hour increments. In a typical application, 
200 hours (default) of run time is approximately 30 days. 
After the selected time of blower operation, the thermostat 
will  display 

“Change  Filter”

  as  a  reminder  to  change  or 

clean  your  air  filter. When 

“Change  Filter”

  is  displayed, 

press the RUN/HOLD button to clear the display and restart 
the time to the next filter change. A selection of OFF will 
cancel this feature.

OPERATION 

CHECK THERMOSTAT OPERATION

If  at  any  time  during  testing  your  system  does  not  operate 
properly, contact a qualified service person.
Turn on power to the system.

Fan Operation

If your system 

does not

 have a 

G

 terminal connection, skip to 

Heating System

.

1.  Move fan switch to 

ON

 position. The blower should begin to 

operate.

2.  Move fan switch to 

AUTO

 position. The blower should stop 

immediately.

Heating System

1.  Move  SYSTEM  switch  to 

HEAT

  position.  If  the  auxiliary 

heating system has a standing pilot, be sure to light it.

2.  Press 

 to adjust thermostat setting to 1° above room 

temperature. The system should begin to operate. 

3.  Press 

  to  adjust  temperature  setting  below  room 

temperature. The heating system should stop operating.

MANUAL OPERATION

• 

HOLD TEMPERATURE

  — With  the  SYSTEM  switch  set 

to 

HEAT

 or 

COOL

, momentarily press RUN/HOLD button. 

HOLD

  will  be  displayed.  Use 

  or 

  to  adjust  the 

temperature. The thermostat will hold the room temperature 
at the selected setting until you press RUN/HOLD button to 
start program operation again.

• 

TEMPERATURE  OVERRIDE  (TEMPORARY  HOLD)

    — 

Press 

 or 

 until the temperature you want is displayed. 

The  thermostat  will  override  current  programming  and 
keep the room temperature at the selected temperature for 
2 hours or until the next program period begins. Then the 
thermostat will automatically revert to the program.

3.  Press 

  to  adjust  temperature  setting  above  room 

temperature. The cooling system should stop operating.

Содержание 1F87-0261

Страница 1: ...7 0261 Thermostat Model Programming Choice 1F87 0261 7 Day Programmable SPECIFICATIONS Electrical Rating Battery Power mV to 30 VAC 50 60 Hz or DC Input Hardwire 20 to 30 VAC Terminal Load 1 0 A per terminal 1 5A maximum all terminals combined Setpoint Range 45 to 90 F 7 to 32 C Differential Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Opera...

Страница 2: ...e O B switch on this thermostat is factory set to the O position This will accommodate the majority of heat pump applications which require the changeover relay to be energized in COOL If the thermostat you are replacing or the heat pump being installed with this thermostat requires a B terminal to energize the changeover relay in HEAT the O B switch must be moved to the B position Mounting Hole M...

Страница 3: ...of the next program period To deactivate the EMR function see the Configuration menu on Page 5 The thermostat will then wait until the programmed time to start the system for a temperature change INSTALLATION WIRING DIAGRAMS R C 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 2 Typical wiring diagram for single transformer single stage systems TRANSFORMER Class II Current Limited Changeove...

Страница 4: ...lace the cover line up the cover with the base and press until the cover snaps onto the base The Thermostat Buttons and Switches 1 Raises temperature setting 2 Lowers temperature setting 3 TIME button 4 SYSTEM switch COOL OFF HEAT EMER 5 PRGM program button 6 FAN switch ON AUTO 7 RUN HOLD program button The Display 8 Indicates days of the week 9 Indicates setpoint temperature This is blank when sy...

Страница 5: ... humidity in the home will be lower and a higher setpoint temperature will feel comfortable After 20 minutes of run time the thermostat will start increasing the setpoint temperature in steps of less than one degree as the system continues to run These adjustments will eventually cause the system to satisfy the thermostat and turn the system off to reduce the energy consumption When the Cool Savin...

Страница 6: ...reminder On or OFF If selected On press RUN HOLD to select the time period from 25 to 1975 hours in 25 hour increments In a typical application 200 hours default of run time is approximately 30 days After the selected time of blower operation the thermostat will display Change Filter as a reminder to change or clean your air filter When Change Filter is displayed press the RUN HOLD button to clear...

Страница 7: ...t Current Time and Day 1 Press TIME button once The display will show the hour only EXAMPLE 2 Press and hold either or until you reach the correct hour and AM PM designation AM begins at midnight PM begins at noon 3 Press TIME once again The display window will show the minutes only EXAMPLE 4 Press and hold either or until you reach the correct minutes 5 Press TIME once again The display will show...

Страница 8: ...g Program 1 Move SYSTEM switch to COOL position 2 Follow Enter Heating Program for entering your cooling program using your selected cooling times and temperatures PROGRAMMING If the outside temperature is below 50o F disconnect power to the cooling system before programming Energizing the air conditioner compressor during cold weather may cause personal injury or property damage CAUTION CHECK YOU...

Страница 9: ...hermostat clicks in Cooling if the compressor lock out option is selected in the configuration menu Item 6 Heat Cool or Fan Runs Constantly 1 Possible short in wiring 2 Possible short in thermostat 3 Possible short in Heat Cool Fan system 4 Fan Switch set to Fan On Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal screw...

Страница 10: ...10 NOTES ...

Страница 11: ...11 NOTES ...

Страница 12: ...www white rodgers com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 ...

Отзывы: