Page 8
15627-5-0807
Clearances: When facing the front of the fireplace heater the
minimum clearances to combustible construction (material) are
the following:
Open in front to provide service, access, and clearance to
construction.
Top of appliance (ceiling)
36 (inches)
Draft Diverter to Rear Wall
2 (inches)
Side Wall
6 (inches)
Heater Corners (45° angle) to Wall
4 (inches)
Floor
0 (inches)
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or
other combustible material,
other than wood flooring,
the appli-
ance shall be installed on a metal or wood panel extending the
full width and depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is primarily for rugs that may
be extremely thick and light-color tile that can discolor.
(914mm) TO CEILING
OR HORIZONTAL
PROJECTION ABOVE
APPLIANCE
Figure 2
Figure 3
Figure 4
CLEARANCES