Page 27
15627-5-0807
CAUTION:
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To shut heater off: Turn temperature dial
or thermostat to lowest setting. Turn knob on gas control
to "OFF", depressing slightly. Do not force.
Cleaning
The blower wheel will collect lint and could require cleaning once
a year. If the air output decreases or the noise level increases, it
indicates a dirty wheel.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to
oil blower motor.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the
National Electrical Code, ANSI/NFPA 70 or Canadian
Electrical Code, CSA C22.1,
if an external electrical source
is utilized.
This appliance is equipped with a three-prong
[grounding] plug for your protection against shock hazard
and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected to
the receptacle mounting screws. With this wire completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
PARTS LIST
Index Part
No.
No.
Description
1
R-1454
Brass Bushing (4 Required)
2
R-1499 Rubber Grommet (4 Required)
3
CI-002
Blower Housing
4
R-1517 Tinnerman Clip (4 Required)
5
R-2804-A Blower Assembly
6
CI-003
Blower Housing Cover
7
R-2099 Cord Set
8
R-3767-A Wire Harness
9A
CI-004
Fan Control Bracket
(Use with CIBV-30 and CIVF-25)
9B
CI-325
Fan Control Bracket
(Use with CIDV-30)
10
R-2503 Fan Control
11
R-2805 Auto/Off/On Switch
12
CI-220
Fan Control Shield
(Use with CIVF-25)
13
R-1410 Bushing 7/8" Diameter