WhisperKool EXTREME 5000TI Скачать руководство пользователя страница 25

Page 25

STANDARD CONTROLLER FUNCTIONS - XR70CX

If your unit is installed through the wall and does not have a remote keypad you will have the Xr70CX Controller.

Button

Normal Functions

ON/OFF

• 

The ON/OFF button allows the customer the convenience of turning the refrigera-

tion system ON or OFF, from the control panel.  This feature does not disconnect 

power from the unit.  In order for the power to be shut off from the unit, the power 

cord must be unplugged from the wall receptacle.

• 

Press the ON/OFF button once for button application.

Up and Down 

Arrows

• 

Use these buttons to scroll up or down the CPSM (Customer Preference Selection 

Mode)

 

menu. 

• 

Displays the Highest and Lowest temperature sensed by the Bottle Probe.  This 

feature allows the customer instant access to the recorded data applicable to the 

Bottle Probe Temperatures, it can be easily reset to reflect current temperatures.

1.  Press the “UP” arrow, or the “Down” arrow once, and the Highest or Lowest Tempera-

ture (Hi/Lo) sensed by the Bottle Probe, will be displayed.  

2.  To reset the Hi/Lo, press and hold the “Set” button when the Hi/Lo value is displayed 

on the Digital Display, continue to hold the “Set” button until “rst” appears on the 

digital display and then blinks.  This will erase the past recorded “Temperature Data 

History” and start recording, from the current time and temperature, forward.  Tem-

peratures displayed would reflect Bottle Probe Temperatures from that point in time, 

and beyond.

3.  The Hi/Lo feature should be reset at initial “Start-Up” and after the Cellar or Cabinet 

has obtained normal operating temperatures, which is generally 55°F.

Cellar PreChill (CPC)

The CPC Feature is activated by pressing the Up button for 3-5 seconds, and the CPC 

logo will be displayed on the digital display.  The CPC feature can be terminated by 

pressing the Up button for 3-5 seconds, or the feature will self terminate after 6 hrs.

1.  The (CPC) Feature may be used to Pre-Chill the Cellar prior to loading it with Warm 

Product.  The feature will shift the Set Point down to a lower setting of 52°F, for the 

next 6 hours.  After the 6 hour time period, the Set Point will automatically return to 

the original Set Point.  

2.  The CPC feature can be conveniently adjusted to the customer’s specific needs, by 

accessing the “Customer Preference Select Mode” (CPSM).  See Customer Preference 

Select Mode Instructions.

Содержание EXTREME 5000TI

Страница 1: ...5000ti EXTREME OWNER S MANUAL The Coolest Thing In Wine Storage For 5000ti 5000tiR ...

Страница 2: ...or any purpose in whole or in part without the written consent of WhisperKOOL Every effort has been made to ensure that the information in this manual is accurate WhisperKOOL is not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hard ware at any time without notice Vinothèque and WhisperK...

Страница 3: ...peration Standard and Remote Standard Control Functions Standard Wire Schematic Remote Controller Functions Remote Wire Schematic Maintenance Schedule Troubleshooting Guide Technical Assistance Accessories for Cooling Unit Installation Terms and Conditions 4 5 6 7 8 9 10 15 16 19 20 21 23 24 25 28 29 32 33 34 36 36 37 We manufacture test and certify 100 of our wine cooling units in the USA By sour...

Страница 4: ... HIGH MED LOW WHISPERKOOL Series QUICK REFERENCE GUIDE Front Side View Rear View Controller Bottle Probe Probe Input Front Grille Control Panel see page 15 for details Speed Control Posterior Grille Drain Port Rear Power Option ...

Страница 5: ...ton Turns the Cooling Unit ON OFF 1 Defrost Compressor Hi Bottle Temp History Scroll Button 1 Cellar Pre Chill Button 3 5 Low Bottle Temp History Scroll Button Push to see the min stored temperature In programming mode use to browse the parameter codes or decrease the displayed value 1 Inactive Display and modify set point In programming mode it selects a parameter confirms an opera tion Hold for ...

Страница 6: ...all Installation or Ducted If the unit is going to be ducted you would need to use the highest fan speed The higher fan speed is designed to support the reduction in airflow created by the ductwork For the thru the wall application the fan speed selection will depend on the cellar size insula tion factor door seal and desired wine temperature When initially installing the unit set the fan speed to...

Страница 7: ...unit designed to be used as a forced air through the wall unit or as a remote mount unit with external ductwork connections How Does the WhisperKOOL Extreme Series Work The WhisperKOOL Extreme Series cooling system is especially designed for the use and application to maintain opti mal conditions for wine storage and aging The system is fully self contained and can be installed as a Thru The Wall ...

Страница 8: ...units are manufactured in the USA and tested prior to shipment Review the Packing Slip to Verify Contents Check the model number to ensure it is correct Check that all factory options ordered are listed If any items listed on the packing slip do not match your order information contact WhisperKOOL Customer Service immediately Check the Box for the following contents Mounting Bracket 14 1 4 2 Mount...

Страница 9: ...hile the unit is running and working properly the air discharged from the front should be 10 15 F cooler than the air in the room This means that in an environment where the air is 80 F the unit will discharge air that is 65 70 F 6 It is REQUIRED to install a drain line to remove excess condensation from the unit 7 The WhisperKOOL unit is intended for use in properly designed and constructed wine ...

Страница 10: ...or in some cases blown in insulation is used It is very important that all walls and ceilings are insulated to keep the cellar temperature as consistent as possible during the summer and winter months The R value or quality of insulation is determined by the rate at which heat passes through the insulation The higher the R value the more resistant the insulation is to conducting heat Using higher ...

Страница 11: ... air and replacing it with cool air Mounting the unit low in the room will result in a temperature variation in the room due to the unit s inability to draw warm air from the ceiling of the cellar to the unit itself and cold air settling to the floor Door and Door Seal An exterior grade 1 3 4 door must be installed as a cellar door It is very important that weather stripping is attached to all 4 s...

Страница 12: ...er to dissipate heat away from the unit If ventilation is inadequate the exhaust will heat up the area or room and adversely affect the unit s ability to cool In some cases it may be ad visable to install a vent fan to dissipate heat within the exhaust area on the backside of the unit However you must have a fresh air inlet as well If your unit requires ducting please contact WhisperKOOL Customer ...

Страница 13: ...m with vertical lines Using a saw cut along the uppermost horizontal line until your saw reaches the stud Turn the saw around inserting it into the cut you have just made and cut toward the opposite stud so that you have a clean hori zontal cut between the two studs Be careful not to cut into the studs themselves Now make the second horizontal cut from stud to stud on the line 16 1 4 below the fir...

Страница 14: ...hat the Whis perKOOL system will fit snugly through the framed cut out Frame the hole with two by four supports Once the horizontal lines have been cut make verti cal cuts using the inside edge of the studs as a guide Once you have made both vertical cuts you should have a rectangular hole in the sheetrock Now you have to make the same hole on the other side of the wall Since you already have one ...

Страница 15: ...ide of the unit inside the cellar the other is located on the rear of the unit outside of the cellar Use the selector switch located on the right side of the unit to select which power inlet you would like to utilize Meaning if you would like to plug the unit into a socket outside of the cellar set the selector switch to rear if you would like to plug the unit into a socket inside of the cellar se...

Страница 16: ...ith the half shears on the unit depending on the desired mounting location secure using the 1 2 self tapping screws provided Refer to the illustration below for the location of the half shears 2 Retrofit your current WhisperKOOL cooling unit 3 1 4 THROUGH THE WALL INSTALLATION without ductwork Applying Insulation Tape Locate the four precut pieces of black foam tape included with the system There ...

Страница 17: ... flange should not be covered in case the unit needs to be removed for servicing Location of Supply and Return Grilles Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes air circulation in the room Avoid short circulation of the air Do not Install through the wall return air grilles at floor level as they will collect dust from the floor Mount the un...

Страница 18: ...ing WRONG Drainline is under water Drain Line All units come with a drain line for additional removal of excessive condensate It is mandatory to install the drain line attachment During operation the cooling unit will strip excess water from the air in order to maintain the proper level of humidity within the cellar However in extreme humidity additional condensate will be removed Thus the drain l...

Страница 19: ...Wall or 3 place the grille on the condenser end and line up the holes on the grille with the holes on unit location 4 Use the 8 self tapping screws provided to fasten the grille to the unit For a flush installation place the grille on the condenser side and then place the mounting bracket over the grille sides stacking them Align the holes and fasten with the 8 self tapping screws provided It is r...

Страница 20: ...s 1 Wine temperature is kept in a very precise controlled environment This assures a consistent temperature 2 By measuring the liquid temperature rather than air the unit will operate 75 80 of the time To Use the thermostat 1 Locate an empty wine bottle 2 Fill 3 4 full with room temperature tap water 3 Place bottle probe securely into bottle 4 Place bottle with probe level and to the side of the u...

Страница 21: ...it or up to 300 feet away with the extend ed connection wire To install the remote controller remove the mounting bracket and secure the bracket to the wall in the desired location Reattach the controller to the bracket Attach the connection wire as shown below with the red wire in the upper connection slot and the black wire in the lower slot Red Wire Mounting Bracket Black Wire REMOTE CONTROLLER...

Страница 22: ...TM TM Remote Controller Bottle Probe Cooling Unit Below is an illustration of one possible way to configure the remote controller in a wine cellar Connection wire in Side Mount configuration Connection wire in Rear Mount configuration ...

Страница 23: ...nvironments and a low setting for super quiet operation Fan Speed Selector Switch Low Med High The cooling unit fans operate on 3 speed settings Low Medium and High For optimum sound and energy efficiency select the lowest fan speed that will maintain the desired cellar temperature High speed is recommended for initial cellar cool down extreme temperature conditions and ducted installations SET 5 ...

Страница 24: ...the refrigeration system to equalize prior to starting the compressor Defrost Cycle The Defrost Cycle is a precautionary measure as icing or frosting of the coil does not occur during normal operation The system will go through a defrost cycle when the evaporator temperature reaches 26 Dur ing the defrost cycle the indoor fan will provide air flow across the indoor coil which will evaporate any fr...

Страница 25: ...n when the Hi Lo value is displayed on the Digital Display continue to hold the Set button until rst appears on the digital display and then blinks This will erase the past recorded Temperature Data History and start recording from the current time and temperature forward Tem peratures displayed would reflect Bottle Probe Temperatures from that point in time and beyond 3 The Hi Lo feature should b...

Страница 26: ...ess and hold the Set button during the display of the Hi Low Temperature Data History hold button unit rst blinks on display and it will erase the past recorded data file and start recording from the current time and temperature 4 Press the Set and the Down Arrow buttons simultaneously for 10 15 seconds and you will access the Customer Preference Selection Mode CPSM The CPSM allows the customer to...

Страница 27: ...is setting will decrease the set point and an increase in this feature will increase the set point AUX AUX indicates that the evaporator temperature is below 26 Alarm Codes Message Cause Solution P1 Bottle Probe is Unplugged Attach Bottle Probe to Unit Faulty Bottle Probe Connection 1 Check Bottle Probe attachment at circular connector 2 Check Bottle Probe connection at green terminal block on bac...

Страница 28: ... 3 4 2 7 8 6 1 0 9 10 11 12 Max 20A 5 A 16 60 8 A 120V 1 2 3 4 5 6 7 8 Fan 8 A Evap Line Cmp Front Receptacle Rear Receptacle Cond Fan Evap Fan Compressor 15 Amp Circuit Breaker 2 1 3 5 4 6 RED GREY BLACK BLUE RED GREY BLACK BLUE BROWN WHITE BROWN WHITE Crankcase Heater ...

Страница 29: ...splay continue to hold the Set button until rst appears on the digital display and then blinks This will erase the past recorded Temperature Data History and start recording from the current time and temperature forward Tem peratures displayed would reflect Bottle Probe Temperatures from that point in time and beyond 3 The Hi Lo feature should be reset at initial Start Up and after the Cellar or C...

Страница 30: ...w buttons simultaneously for 3 5 seconds and you will access the Customer Preference Selection Mode CPSM The CPSM allows the customer to Fine Tune the Control Operating System to their applicable choice The following CPSM options are available for adjustment Fon Humidity Management Enhancement This parameter is normally set at 0 which should provide adequate relative humidity for the cellar An inc...

Страница 31: ... Probe is Unplugged Attach Bottle Probe to Unit Faulty Bottle Probe Connection 1 Check Bottle Probe attachment at circular connector 2 Check Bottle Probe connection at green terminal block on back of controller Defective Bottle Probe Replace the Bottle Probe P2 Faulty Evaporator Probe Connection Check Evaporator Probe connection at green terminal block on back of controller Defective Evaporator Pr...

Страница 32: ...RE SCHEMATIC XW260K CMR NC C NO 3 4 2 7 8 6 1 0 Front Receptacle Rear Receptacle Cond Fan Evap Fan Compressor 15 Amp Circuit Breaker 2 1 3 5 4 6 RED GREY BLACK BLUE RED GREY BLACK BLUE BROWN WHITE BROWN WHITE Crankcase Heater Line Neutral ...

Страница 33: ...l 3 Wash with warm water 4 Dry off filter by shaking excess water from filter 5 Open access door and add chlorine tablets to drip tray Annually 1 Replace filters if worn or plugged beyond cleaning 2 Use a vacuum with brush attachment to clean coils Be careful not to crush coil fins when cleaning 3 Inspect for corrosion 4 Check wiring connections and integrity of cords 5 Examine duct work for crack...

Страница 34: ...3 Make sure all fans are working and there are no airflow obstruction Make sure there are no air gaps around the door If door seal is damaged replace it Lower the set point Observe ice formation pattern If only part way up the coil face unit could be low on refrigerant If so call Customer Service at 800 343 9463 TROUBLESHOOTING GUIDE Unit has ice forming on the evaporator Possible Cause Evaporator...

Страница 35: ...lem repeats call cus tomer service Solution Call Customer Service at 800 343 9463 Call Customer Service at 800 343 9463 Solution Move bottle probe to a more central location Call Customer Service at 800 343 9463 Call Customer Service at 800 343 9463 Call Customer Service at 800 343 9463 Solution Raise the Fon setting to increase the humidity level Unit leaks water Possible Cause Unit is not level ...

Страница 36: ...le Protects the Platinum Extreme systems from the weather elements when placed on the exhaust side Small Exterior Grille used for Platinum Extreme 5000ti 5000tiR Condensate Pump Kit The condensate pump kit is designed as an automatic condensate removal pump for water dripping out of our cooling units drain line The pump is controlled by a float switch mechanism that turns the pump on when approxim...

Страница 37: ... and Conditions The only language in which WhisperKOOL states these Terms and Conditions is English WhisperKOOL reserves the right in its sole discretion to change these Terms and Conditions at any time for any reason without notice WhisperKOOL shall not be liable to Purchaser for any delay of delivery of a Product caused by Force Majeure or any other cause beyond WhisperKOOL s control 2 WHISPERKO...

Страница 38: ...cedures set forth by WhisperKOOL in WhisperKOOL s Owner s Manual The Owner s Manual is shipped with each Product and if another copy is needed replacement copies can be downloaded from WhisperKOOL s website www whisperkool com or by contacting WhisperKOOL directly for a new copy of the Owner s Manual b It is highly recommended that the End User obtain the assistance of a wine storage professional ...

Страница 39: ...and duties if applicable b WhisperKOOL retains a security interest in each Product until payment in full c Every provision of these Terms and Conditions shall be construed to the extent possible so as to be valid and enforceable If any provision of these Terms and Conditions is held by a court of competent jurisdiction to be invalid illegal or otherwise unenforceable such provision will to the ext...

Страница 40: ...NOTES ...

Страница 41: ...NOTES ...

Страница 42: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...

Отзывы: