INFORMATION
EN / W-SQ12 for mobile applications / January 2009
7
2 INFORMATION
2.1
SAFETY
2.1.1
General
When
correctly
installed
and
used
in
normal
circumstances this generating set fulfils EC safety
regulations. This generating set could be part of an
installation or could be used in a way that additional
regulations of the EC or other authorities have to be taken
into account.
Circumstances could make it also necessary
to take additional measures. Be aware of wet
conditions
and
hazardous
environments
caused by explosive gases etc
2.1.2
Electrical safety
The voltage of 230 Volt generated by this
generating set is dangerous and if instructions
and procedures are not strictly observed may
result in electrical shock which will result in
severe personal injury or loss of life.
Realise that people are not used to have
230V available on a vehicle. Put warning
signs on wall sockets and on junction boxes.
Instruct non-regular users of the vehicle. Warn
maintenance personal of garages that do
service on the vehicle.
•
Check all wiring at least once a year. Defects,
such as loose connections, burned cables etc.
must be repaired immediately.
•
Do not work on the electrical system if it is still
connected to a current source. Only allow
changes in your electrical system to be carried
out by qualified electricians.
•
Connection and protection must be done in
accordance with local standards.
•
Using the auto-start/stop (interval) mode the
generator can start unexpectedly. When
working on the electrical system, the 3 Amp
fuse must be removed from the control panel
and the battery plus cable must be removed
from the battery.
Warning signs indicate parts which could be
live.
2.1.3
Earth insulation failures
According to local regulations and depending on the
application it could be necessary to take measures for
protection against earth insulation failures.
In the standard delivery “neutral” and “ground” are not
connected. To make a connection between “neutral” and
“ground” could be necessary as part of a specific
insulation failure protection system.
In all situations the transfer switches between
shore, inverter and generator should switch
both neutral and L1. Of course this is the case
when using a Mastervolt Mass Systemswitch.
2.1.4
Installation
Whisper generating sets are not self contained and have
to be properly installed in enclosed areas. Installation
includes measures to be taken to outlet exhaust fumes
which contain carbon monoxide and are extremely
dangerous. Carbon monoxide (CO) is an invisible
odourless gas. Inhalation produces headache, nausea or
death.
Installation
includes
measures
for
proper
ventilation, safe electric connections, safe installation of
the starting battery, proper fitting of the cooling system and
fuel pipes etc. Refer to the installation manual.
Do not use the generator set when the vehicle
is inside a building or in other enclosed area’s.
Be aware using the generator in wind still
conditions, when the exhaust fumes could
accumulate under, around or even in the
vehicle.