10 WhisperPower Battery Charger
12 V 100 A
Digital Display:
•
‘
CH1
’, ‘
CH2
’ and ‘
CH3
’ represent Battery Bank 1, 2 and 3
respectively. With ‘
CH1
’ turned on, the numerical value on
the display shows individual battery information like battery
voltage in ‘
V
’ or charging current in ‘
A
’. ‘
CH 2
’ and ‘
CH 3
’ will
always turn on together, the numerical value on the display
shows the total charging current in ‘
A
’
•
‘
GEL
’, ‘
AGM
’, ‘
Flooded
’, ‘
Lithium
’ and ‘
Program
’ represent
different battery types setting.
•
‘
Auto
’ indicates Silent Mode is activated
•
‘
Mode
’ only turns on during the setting of charging stage
Mode 2 - (2 stages: Bulk and Absorption stage)
Mode 3 - (3 stages: Bulk, Absorption and Float stage)
•
‘
Temp
’ only turns on when manually setting of battery
temperature.
Battery Charging Voltage:
Voltage default settings
Battery Type
Absorption
Float
Equalization
GEL
14.4 V
13.7 V
N.A.
AGM
14.7 V
13.6 V
N.A.
Flooded
14.4 V
13.3 V
15.5 V (See Note 1)
Lithium
Constant 13.9 – 14.8 V (0.1V Step, See Note 2)
N.A
Program
13.8 – 14.8 V
13.0 – 13.8 V
N.A
Note 1: Equalization setting can only be used on flooded battery type selection only.
See more details on the
Procedure to Equalize the Flooded Battery section
Note 2: Charger will terminate charging when charging current drops below the set termination value.
Battery Bank Size Recommendation:
The battery charging current rating is based on the battery size. When charging
GEL, AGM
and
Flooded
batteries, each battery bank should meet the minimum Ah rating as shown. If a smaller
size battery bank is used, set the current rating to a lower value to match with the battery bank
size. Normally, the maximum charger current rating is based on half the battery bank capacity.
Capacity Imax settings
Current Setting (A)
100
60
40
20
10
Minimum Battery Capacity (Ah)
200
120
80
40
20
When charging Lithium battery, consults the Lithium battery manufacturer for maximum
allowable charging current.
Power Supply
The charger can also be set to power supply mode (
Program
setting). With this setting, the
charger will only provide constant voltage and current to CH 1, while CH 2 & 3 (Bank 2 & 3)
are disabled. No DC voltage or current will be supplied to Ch 2 & 3 even if battery banks are
connected to the two channels. The charger will act as a constant voltage power supply with
user selected supply voltage and maximum current.
Содержание Supreme WP-BC 12/100-3
Страница 1: ...12 V 100 A WP BC 12 100 3 Enjoy Green Energy Battery Charger Supreme whisperpower com User Manual ...
Страница 2: ...2 WhisperPower Battery Charger 12 V 100 A ...
Страница 24: ...24 WhisperPower Battery Charger 12 V 100 A ...
Страница 25: ...WhisperPower Battery Charger 12 V 100 A 25 ...
Страница 26: ...26 WhisperPower Battery Charger 12 V 100 A ...
Страница 27: ...WhisperPower Battery Charger 12 V 100 A 27 Proposed charging profile 2020 for Litium cell balancing ...