Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
■
Select the route that will provide the straightest and most
direct path outdoors.
■
Plan the installation to use the fewest number of elbows and
turns.
■
When using elbows or making turns, allow as much room as
possible.
■
Bend vent gradually to avoid kinking.
■
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best drying
performance
■
Use the Vent system chart below to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the
Vent system chart. Exhaust systems longer than those
specified will:
■
Shorten the life of the dryer.
■
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will help
to achieve the best drying performance.
Vent system chart
NOTE: Side exhaust installations add a 90º turn inside the dryer.
To determine maximum exhaust length, add one 90º turn to the
chart.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See “Determine vent path” in “Plan Vent Systems.” Avoid 90º
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
Level Washer/Dryer
Properly leveling your washer/dryer avoids excessive noise and
vibration.
1. Check the levelness of the washer/dryer by placing a level on
the top edge of the washer, first side to side, then front to
back.
Number of
90º turns
or elbows
Type of Vent
Box or
Louvered
hoods
Angled
hoods
0
Rigid metal
Flexible metal
37 ft (11.3 m)
25 ft (7.6 m)
35 ft (10.7 m)
20 ft (6.1 m)
1
Rigid metal
Flexible metal
32 ft (9.7 m)
21 ft (6.4 m)
27 ft (8.2 m)
16 ft (4.9 m)
2
Rigid metal
Flexible metal
24 ft (7.3 m)
15 ft (4.6 m)
19 ft (5.8 m)
10 ft (3.0 m)