ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is 

recommended that a separate circuit breaker serving only this appliance be provided.

Floor drain system requires a Siphon Break Kit (Part Number 285834), 2 

Connector Kits (Part Number 285835), and an  

Extension Drain Hose (Part Number 285863) that may be  

purchased separately. See “Alternate Parts.” Minimum siphon break 

height: 28" (710 mm) from bottom of washer. (Additional hoses may be 

needed.)

Minimum diameter for a standpipe drain: 2" (51 mm). Minimum carry-

away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm)  

diameter to 1" (25 mm) diameter Standpipe Adapter Kit is  

available (Part Number 3363920). Top of standpipe must be at  

least 24" (60 cm) high; install no higher than 49" (125 cm) from bottom of 

washer. If you have an overhead sewer and need to pump higher than 96 

inches, a sump pump and associated  

hardware are needed. See “Alternate Parts.”

Wall standpipe drain system

Laundry tub drain system

Minimum capacity: 20 gal. (76 L). Top of laundry tub must  

be at least 24" (60 cm) above floor; install no higher than  

49" (125 cm) from bottom of washer. 

4

1

/

2

"

(114 mm)

max. 49"

(1250 mm)

min. 24"

(60 mm)

Floor standpipe drain system

4.5"

(114 mm)

4

1

/

2

"

(114 mm)

max. 48"

(1219 mm)

min. 30"

(762 mm)

See requirements for floor standpipe drain system.

max. 49"

(1250 mm)

min. 24"

(60 mm)

max. 49"

(1250 mm)

min. 24"

(60 mm)

4

1

/

2

"

(114 mm)

4

1

/

2

"

(114 mm)

Floor drain system

Drain system can be installed using a floor drain, wall standpipe,  floor 

standpipe, or laundry tub. Select method you need. 

IMPORTANT:

 To avoid siphoning, only 4

1

2

" (114 mm) of drain hose 

should be inside standpipe. Always secure drain hose with cable tie.

Location Requirements (cont.)

Closet installation (washer only):

34"

(864 mm)

1"

(25 mm)

4"

(102 mm)

24 in.

min.

(155 cm

2

)

48 in.

min.

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

1"

(25 mm)

18"  

(457 mm)

* Recommended   

spacing. Minimum  

0" (0 mm)

*

*

*

max. 49" 

(125 cm) 

min. 24" 

(60 cm)

max. 49" 

(125 cm) 

min. 24" 

(60 cm)

max. 49" 

(125 cm) 

min. 24" 

(60 cm)

Drain System