72
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gal. (64 L) per minute. A 2" (51 mm)
diameter to 1" (25 mm) diameter Standpipe Adapter Kit is
available. Top of standpipe must be at least 24" (60 cm) high;
install no higher than 49" (125 cm) from bottom of washer/dryer.
If you have an overhead sewer and need to pump higher than
96" (2.44 m), a sump pump and associated hardware are needed.
See “Assistance or Service.”
Wall standpipe drain system
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must
be at least 24" (60 cm) above floor; install no higher than
49" (125 cm) from bottom of washer/dryer.
)
m
m
4
1
1
(
)
m
m
4
1
1
(
See requirements for floor standpipe drain system.
Max..
x
a
m .
x
a
m
(125 cm)
m
m
0
5
2
1
m
m
0
5
2
1
Min..
n
i
m .
n
i
m
((
))
(60 cm))
m
m
0
6
(
)
m
m
0
6
(
The drain system can be installed using a floor drain, wall
standpipe, floor standpipe, or laundry tub. Select the method
you need.
IMPORTANT:
To avoid siphoning, only 4.5" (114 mm) of drain
hose should be inside standpipe. Always secure drain hose with
cable tie.
Floor standpipe drain system
Drain System
4.5"
(114 mm)
4.5"
(114 mm)
Max. 49"
(125 cm)
Min. 24"
(60 cm
Max. 49"
(125 cm)
Min. 24"
(60 cm
4.5"
(114 mm)
Max. 49"
(125 cm)
Min. 24"
(60 cm)
Floor drain system
Floor drain system requires a Siphon Break Kit, two Connector
Kits, and an Extension Drain Hose that may be purchased
separately. See “Assistance or Service.” Minimum siphon break
height: 28” (710 mm) from bottom of washer/dryer (additional
hoses may be needed).