9
2.
Connect neutral wire
Connect neutral wire (white or center wire) (C) of power supply
cord to center, silver-colored terminal block screw (B). Tighten
screw.
C
B
Direct Wire
3.
Connect remaining wires
Connect remaining wires to outer terminal block screws. Tighten
screws. Finally, reinsert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down screw.
now, go
to Venting Requirements.
Unscrew removable conduit connector and any screws from
a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief).
Put threaded section of strain relief through hole below terminal
block opening, screw removable conduit connector onto strain
relief threads.
1.
Attach direct wire strain relief
Direct wire strain relief:
Put direct wire cable through strain relief. Strain relief should be a
tight fit with dryer cabinet and be in a horizontal position. Tighten
strain relief screw against direct wire cable.
now go to step 1
for 4-wire direct wire connection, step 1 for 3-wire direct wire
connection, or step 1 for optional 3-wire connection.
2.
Attach direct wire cable
to strain relief