14
Determine vent path:
Select route that will provide straightest and most direct
■
path outdoors.
Plan installation to use fewest number of elbows and turns.
■
When using elbows or making turns, allow as much room
■
as possible.
Bend vent gradually to avoid kinking.
■
Use as few 90° turns as possible.
■
Determine vent length and elbows needed for best
drying performance:
Use following Vent system chart to determine type of vent
■
material and hood combinations acceptable to use.
noTE:
Do not use vent runs longer than those specified in
Vent system chart.
Exhaust systems longer than those specified will:
Shorten life of dryer.
■
Reduce performance, resulting in longer drying times
■
and increased energy usage.
Attach short hose and
“Y” connector
2.
If space permits, attach the brass female end of the “Y”
connector to the cold water faucet. See figure A.
If “Y” connector cannot be attached directly to the cold water
faucet, the short hose must be used. See figure B. Attach short
hose to cold water faucet. Screw on coupling by hand until it is
seated on faucet. Then attach “Y” connector to brass male end
of the short hose. Screw on coupling by hand until it is seated
on connector.
A
B
CONNECT INLET HOSE
The dryer must be connected to the cold water faucet using
the new inlet hoses. Do not use old hoses.
Turn cold water off, remove and
replace rubber washer
1.
Turn cold water faucet off and remove washer inlet hose.
Check and see if rubber washer is in the “Y” connector. Remove
old rubber washer from inlet hose and replace with new rubber
washer provided.
Connect vent to exhaust hood
2.
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4” (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal all
joints. Do not use duct tape, screws, or other fastening devices
that extend into interior of vent to secure vent, because they can
catch lint.
Vent system chart
number of
90° elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
INSTALL vENT SYSTEM
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
The Vent system chart provides venting requirements that will
help achieve best drying performance.
noTE:
Side and bottom exhaust installation have a 90° turn
inside the dryer. To determine maximum exhaust length, add on
90° turn to the chart.
noTE:
If flexible transition vent is used, the length must be
subtracted from the total exhaust length in the vent system chart.