Whirlpool WCC Скачать руководство пользователя страница 4

Do not remove the caps from the lines or system connection 
points until connections are ready to be completed.

Prepare Tubing

All cut ends are to be round, burr free, and cleaned. Failure to 
follow this practice increases the chances for refrigerant 
leaks.

The suction line is spun closed and requires a pipe cutter to 
remove the closed end.

Post Brazing

Cool all welded joints with water or a wet rag.

Piping Size

For the correct tubing size, follow the specification for the 
condenser/heat pump.

Check Orifice and Connect Tubing

1. Loosen the 

¹³⁄₁₆

" nut 1 turn only. 

NOTE: No pressure loss indicates a possible leak.

2. Remove the nut and discard the plastic or brass cap.

3. Remove the check piston to verify it is correct, and then 

replace the piston. See piston kit chart in instructions.

4. Use a tube cutter to remove the spin closure on the suction 

line.

5. Remove the tailpiece clamped to the exterior.

6. Slide the 

¹³⁄₁₆

" nut into position on the tailpiece. 

7. Braze the tailpiece to the liquid tube.

8. Insert the suction line into the connection.

9. Slide the insulation and the rubber grommet at least 18" 

(45.7 cm) away from the braze joint. 

10. Braze the suction line.

11. After the tailpiece has cooled, verify the position of the white 

Teflon

®†

 seal and hand tighten the nut.

12. Torque the 

¹³⁄₁₆

" nut to 20 to 30 ft-lbs. (2.77 to 4.15 m-kg).

13. Replace the suction line grommet and insulation.

ASSISTANCE OR SERVICE

If you need further assistance, you can write to the below 
address with any questions or concerns:

Whirlpool

®

 Home Cooling and Heating

14610 Breakers Drive
Jacksonville, FL 32258

Please include a daytime phone number in your correspondence.

Accessories

To order accessories contact your Whirlpool

®

 Home Cooling and 

Heating dealer.

To protect the unit when welding close to the painted
surfaces, the use of a quenching cloth is strongly advised
to prevent scorching or marring of the equipment finish. 
Solder with a minimum of 5% silver is recommended.

CAUTION

This product is factory-shipped under pressure. Follow 
these instructions to prevent injury.

WARNING

A. Tailpiece
B.

¹³⁄₁₆

" nut

C. Plastic or brass cap

D. Piston

E. White Teflon

®

 seal

A. Suction line with spin closure
B. Rubber grommet

A

B

C

D

E

Excessive torque can cause orifices to stick. Use the 
proper torque settings when tightening orifices.

CAUTION

A

B

WPIO-284B

© 2009. All rights reserved.

®Registered Trademark/TM Trademark of Whirlpool, U.S.A.,

Manufactured under license by Tradewinds Distributing Company, LLC., Jacksonville, Florida

†®Teflon is a registered trademark of Dupont.

8/09

Printed in U.S.A.

Содержание WCC

Страница 1: ...s type of equipment should be determined prior to installation Read this entire instruction manual as well as the instructions supplied in separate equipment before starting the installation All models are designed for indoor installation only Install the conditioned air plenum ducts and air filters not provided in accordance with NFPA 90B Standard for the Installation of Warm Air Heating and Air ...

Страница 2: ...d left front drain connections when installed in the horizontal position Minimum copper or PVC drain lines are recommended NOTE Check local codes before connecting drain lines to an existing drainage system A field fabricated auxiliary drain pan with a drainpipe to the outside of the building is required in all installations over a finished living space or in any area that may be damaged by overfl...

Страница 3: ...o the plastic drain pan Typical drain pipe routings to avoid interference with vent piping are shown in the Typical Drain Pipe Routing illustration Typical Drain Pipe Routing VerifyOrificeSize IMPORTANT The proper orifice size is dependent on indoor coil outdoor unit combination and application Consult the outdoor unit information to determine if the indoor unit has the correct orifice installed C...

Страница 4: ...tailpiece has cooled verify the position of the white Teflon seal and hand tighten the nut 12 Torque the nut to 20 to 30 ft lbs 2 77 to 4 15 m kg 13 Replace the suction line grommet and insulation ASSISTANCE OR SERVICE If you need further assistance you can write to the below address with any questions or concerns Whirlpool Home Cooling and Heating 14610 Breakers Drive Jacksonville FL 32258 Please...

Отзывы: