5
Recessed Area and Closet Installation Instructions
This dryer must not be installed behind a lockable door, a sliding
door, or a door with a hinge on the opposite side to that of the
dryer.
This dryer may be installed in a recessed area or closet. For
recessed area and closet installations, minimum clearances can
be found on the serial tag on the dryer.
The installation spacing is in centimeters (inches) and is the
minimum allowable. Additional spacing should be considered for
ease of installation, servicing, and compliance with local codes
and ordinances.
If closet door is installed, the minimum unobstructed air opening
in the top and bottom is required. Louvered doors with equivalent
air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Recessed front view
Closet side view
Minimum Installation Clearances
Additional clearances for wall, door and floor moldings may be required or if
external exhaust elbow is used.
closet
door
Front
View
7.6 cm (3")
7.6 cm (3")
155 cm
2
(24"
2
)
310 cm
2
(48"
2
)
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
2.5 cm (1")
Closet
door
35.6 cm
(14") max.
2.5 cm (1")
2.5 cm (1")
45.7 cm
(18")*
10.2 cm
(4")
Product Dimensions
Dimensions shown with feet extended 2.5 cm (1") from
bottom of dryer.
left or right
side exhaust
back
exhaust
10.8 cm
(4-1/4")
26 cm
(10-1/4")
35.9 cm
(14-1/8")
10.2 cm
(4")
Exhaust dimensions
74.3 cm
(29-1/4")
An electrical outlet is
required within 1.4 m
(4-1/2 feet) for the
power supply cord
109.5 cm
(43-1/8")
27.9 cm
(11")
97.2 cm
(38-1/4")
68.6 cm (27")
35.6 cm (14")
door clearance
15.9 cm
(6-1/4")
3.8 cm
(1-1/2")
gas line
opening