Location Requirements
IMPORTANT:
Observe all governing codes and ordinances.
■
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
INSTALLATION REQUIREMENTS
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 46 cm (18 inches) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed
■
Flat-blade screwdriver
■
Phillips screwdriver
■
Adjustable wrench that opens to 2.5 cm (1")
■
2.5 cm (1") Hex-head socket wrench
■
Level
■
20 or 30 cm (8" or 10") pipe wrench
■
1/4" socket wrench or 1/4" nut driver
■
Utility knife
■
Vent clamps
■
Pipe-joint compound resistant to LP gas
■
Caulk gun and caulk (for installing new exhaust vent)
■
Tin snips
Parts supplied
Remove parts bag from dryer drum. Check that all parts were
included.
■
4 leveling legs
■
4 gas inlet pipe adapters
Parts needed
Check local codes and gas supplier, and read electrical,
gas and venting requirements before purchasing parts.
Gas supply line must have:
•
Shutoff valve
Rigid gas supply line must be:
•
Minimum 12.5 mm (1/2
"
) ID pipe
Flexible gas supply hose must be:
•
Minimum 10 mm (3/8
"
) ID approved flexible hose
L.P. gas conversion:
Gas conversion kit, part number 279918, available for
purchase from your dealer. Full instructions are supplied
with the kit. Conversion must be made by a competent
technician.
■
Make sure that lower edges of the cabinet, plus the back and
bottom sides of the dryer, are free of obstructions to permit
adequate clearance of air openings for combustion air. See
“Recessed Area and Closet Installation Instructions” for
minimum spacing requirements.
NOTE:
The dryer must not be installed in an area where it will be
exposed to water and/or weather. If room temperature is below
7º C (45º F), automatic cycles may not shut off.
■
Maximum slope under entire dryer should not be more than
2.5 cm (1") . If slope is greater than 2.5 cm (1") , install
Extended Dryer Feet Kit, Part No. 279810. Clothes may not
tumble properly and automatic sensor cycles may not operate
correctly if dryer is not level. Floor must be able to support