When fitting the cover, check that the side rails fit in the
proper head-screws (those used to fix the lower vent cover to
the hood) on the right and left side of the duct.
Install Filters
For non-vented (recirculating) installations
1. Turn off blower and lights. Check that halogen lamps are
cool.
2. Remove the metal grease filters by pushing handle toward
the rear and pull downward.
3. Pull filter toward front.
4. Set the filter face down on a protective cover such as a towel.
5. Install charcoal filter on rear of metal filter with metal wires
provided in filter packaging.
To replace the metal grease filters:
1. Insert back edge of filter into rear channel of the filter
opening.
2. Push handle toward the rear and push filter up.
3. Pull filter toward the front and insert into front channel.
Check Operation
1. Press the “B” button. The light should turn on.
2. Press the “C” button. The blower should turn on at low
speed.
3. Press the “D” button for medium speed or the “E” button for
high speed.
4. Press the “B” button to turn off the light. Press the “C” button
to turn off blower
5. If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
6. Disconnect power supply.
7. Check that the wiring is correct.
8. Replace all parts and panels before operating.
9. Reconnect power.
NOTE: To get the most efficient use from your new range hood,
read the “Range Hood Use” section.
RANGE HOOD USE
Operation
The canopy hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after the
cooking is complete to clear all smoke and odors from the
kitchen.
Range Hood Control Panel
The range hood controls are located on the underside of the
canopy.
Operating the light
1. Press the “B” button to turn on the light.
2. Press the “B” button again to turn off the light.
Operating the blower and adjusting blower speed
1. Press the “C” button for low speed, the “D” button for
medium speed or the “E” button for high speed.
2. Press the “C” button to turn off the blower.
A. Lower vent cover screws
B. Glass visor
C. Aesthetic cover
A. Metal wires
B. Charcoal filter
C. Metal filter
Rear view
A
B
C
A
B
C
A. Indicator light
B. Light button
C. Low speed button
D. Medium speed button
E. High speed button
A. Indicator light
B. Light button
C. Low speed button
D. Medium speed button
E. High speed button
A
B
C
D
E
A
B
C
D
E
Содержание W10018010