4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools needed
Parts supplied
Remove parts from package. Check that all parts are included.
Parts needed
For 7" (17.8 cm) round vented installations
For 3
1
/
4
" x 10" (8.3 x 25.4 cm) rectangular vented
installations
Optional accessories
* For information on ordering, see the “Assistance or Service”
section.
Location Requirements
IMPORTANT:
Observe all governing codes and ordinances.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate.
The model/serial/rating plate is located inside the range
hood on the left wall.
■
Range hood location should be away from strong draft
areas, such as windows, doors, and strong heating vents.
■
Cabinet opening dimensions that are shown must be
used. Given dimensions provide minimum clearance.
Consult the cooktop/range manufacturer installation
instructions before making any cutouts.
■
This range hood is recommended for use with cooktops
with a maximum total rating of 50,000 BTUs or less.
■
Grounded electrical outlet is required. See “Electrical
Requirements” section.
■
All openings in ceiling and wall where range hood will
be installed must be sealed.
■
These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters. See the “Assistance or
Service” section for information on ordering charcoal filters.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, title 24, HUD, Part 280)
or, when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
Product Dimensions
Caulking gun and weatherproof
caulking compound
Jigsaw or keyhole saw
Flat-blade
screwdriver
Wire stripper
#2 Phillips
screwdriver
Metal snips
Pencil
#8-18 x 1"
(4.2 x 25 mm)
flat-head screws
Drywall
anchors
Mounting
brackets
Short Phillips
head screws
Torx T10 adapter
®†
UL listed/CSA approved
wire connectors
7" (17.8 cm)
round
metal vent
system with
wall or roof cap
7" (17.8 cm)
round damper
Part Number
W10355451*
Vent clamps as
required
7" (17.8 cm)
round vent
mounting plate
Part Number
W10388168*
3
¹⁄₄
" x 10"
(8.3 x 25.4 cm) rectangular
metal vent system with
wall or roof cap
Duct tape
Charcoal
filter kit
Part Number
W10386873*
Power
cord kit
Part Number
W10355452*
Stainless steel
cleaner and
polish
Part Number
31462A*
1"
(2.5 cm)
9"
(22.9 cm)
2"
(5.1 cm)
1"
(2.5 cm)
†
®
TORX is a registered trademark of Acument Intellectual Properties, LLC.