6
Electrical Connection - U.S.A. Only
Power Supply Cord
Direct Wire
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover from range.
3. Add strain relief.
Style 1: Power supply cord strain relief
■
Remove the knockout for the power supply cord.
■
Assemble a UL listed strain relief in the opening.
■
Tighten strain relief screw against the power supply cord.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A. Two mounting tabs each side
B. Terminal block cover
C. Hex-head screws
A
B
C
A. UL listed strain relief
A