background image

4

If connecting to a 4-wire system:

This range is manufactured with the ground connected to the 
cabinet. The ground must be revised so the green ground wire of 
the 4-wire power supply cord is connected to the cabinet. See 
“Electrical Connection.”

Grounding through the neutral conductor is prohibited for new 
branch-circuit installations (1996 NEC); mobile homes; and 
recreational vehicles, or an area where local codes prohibit 
grounding through the neutral conductor.

When a 4-wire receptacle of NEMA Type 14-50R is used, a 
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power 
supply cord (pigtail) must be used. This cord contains 4 copper 
conductors with ring terminals or open-end spade terminals with 
upturned ends, terminating in a NEMA Type 14-50R plug on the 
supply end. 

The fourth (grounding) conductor must be identified by a green or 
green/yellow cover and the neutral conductor by a white cover. 
Cord should be Type SRD or SRDT with a UL listed strain relief 
and be at least 4 ft (1.22 m) long.

The minimum conductor sized for the copper 4-wire power 
cord are:

40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding

If connecting to a 3-wire system:

Local codes may permit the use of a UL listed, 3-wire, 250-volt, 
40- or 50-amp range power supply cord (pigtail). This cord 
contains 3 copper conductors with ring terminals or open-end 
spade terminals with upturned ends, terminating in a NEMA Type 
10-50P plug on the supply end. Connectors on the appliance end 
must be provided at the point the power supply cord enters the 
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.

INSTALLATION INSTRUCTIONS

Unpack Range

1. Remove shipping materials, tape and protective film from 

range. Remove oven racks and parts package from inside 
oven.

2. Do not remove the shipping base at this time.

3. On Ranges Equipped with Storage Drawers:

Remove the storage drawer. Use a

 ³⁄₈

" drive ratchet to lower 

the rear leveling legs one-half turn. Use a wrench or pliers to 
lower front leveling legs one-half turn. 

On Ranges Equipped with Warming Drawers:

Use a wrench or pliers to lower the front and rear leveling legs 
one-half turn.

4-wire receptacle (14-50R)

3-wire receptacle (10-50R)

A. Shipping base

WARNING

Excessive Weight Hazard

Use two or more people to move and install range.

Failure to do so can result in back or other injury.

A

A.

³⁄₈

" drive ratchet

B. Rear leveling leg
C. Wrench or pliers
D. Front leveling leg

A. Rear leveling leg
B. Front leveling leg

C. Wrench or pliers

A

B

C

D

A

B

C

Содержание RF265LXTS

Страница 1: ...tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential ha...

Страница 2: ...ction Grounded electrical supply is required See Electrical Requirements section IMPORTANT Some cabinet and building materials are not designed to withstand the heat produced by the oven for baking and self cleaning Check with your builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damage Mobile Home Additional Installation Requirements T...

Страница 3: ...igtail or if local codes do not permit ground through the neutral use a 4 wire power supply cord rated at 250 volts 40 or 50 amps and investigated for use with ranges Electrical Connection To properly install your range you must determine the type of electrical connection you will be using and follow the instructions provided for it here Range must be connected to the proper electrical voltage and...

Страница 4: ...ng If connecting to a 3 wire system Local codes may permit the use of a UL listed 3 wire 250 volt 40 or 50 amp range power supply cord pigtail This cord contains 3 copper conductors with ring terminals or open end spade terminals with upturned ends terminating in a NEMA Type 10 50P plug on the supply end Connectors on the appliance end must be provided at the point the power supply cord enters the...

Страница 5: ...template Remove template from floor 6 Tap plastic anchors into holes with a hammer 7 Align anti tip bracket holes with holes in floor Fasten anti tip bracket with screws provided Depending on the thickness of your flooring longer screws may be necessary to anchor the bracket to the subfloor Longer screws are available from your local hardware store 8 Move range close enough to opening to allow for...

Страница 6: ...train relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or electrical shock WARNING Electrical Shock Hazard Disconnect power before servicing Use 8 gauge copper or 6 gauge aluminum wire Electrically ground range Fail...

Страница 7: ...ct the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to the outer aluminum terminal blocks 6 Securely tighten screws for proper electrical connection 7 Tighten strain relief screws 8 Replace terminal block cover A Removable retaining nut B Strain relief I...

Страница 8: ...hicles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from the range so that it does not contact the range 2 Connect the bare ground wire to the range using the ground link screw and cup washer The ground wire must be attached first and must not contact any o...

Страница 9: ...t secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section LevelRange 1 Place rack in oven Place level on rack and check levelness of range first side to side then front to back If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket On Ranges Equipped with S...

Страница 10: ...qualified technician MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Unplug the power supply cord 2 Slide range forward to complete cleaning or maintenance 3 Check that anti tip bracket is installed Look for the anti tip bracket secur...

Страница 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge ...

Страница 12: ...9762996A 2006 All rights reserved 8 06 Printed in U S A ...

Отзывы: