background image

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE

PART NO. 3957668

PAGE 7

PIÈCE N

o

3957668

3.

Check the wiring and components in the path between these
measurement points by referring to the wiring diagram on
page 15.

4.

Check the drive motor and motor capacitor. Access the drive
motor by removing the toe panel. See Removing the Toe Panel,
page 14.

5.

Disconnect the white motor connector from the drive motor. See
figure 5, page 6.

6.

Check the resistance value of the motor capacitor. See figure 5
for location.

IMPORTANT:

Discharge the capacitor by touching a 20,000 ohm

resistor to the motor capacitor terminals and the capacitor case.

a)

Set the ohmmeter to the R X 10k scale.

b)

Contact the motor capacitor terminals. The resistance should
be low at first and then gradually increase towards infinity.

If the resistance at the motor capacitor is correct, go to step 7.

If the resistance at the motor capacitor is not correct, replace
the capacitor.

3.

Contrôler le câblage et les composants entre ces points de mesure - voir le
schéma de câblage à la page 15.

4.

Contrôler le moteur et le condensateur du moteur. Pour accéder au moteur,
ôter le panneau de plinthe. Voir à la page 14, Dépose du panneau de plinthe.

5.

Débrancher le connecteur (blanc) du moteur. Voir figure 5, page 6.

6.

Contrôler la résistance du condensateur du moteur. Voir sa position à la
figure 5.

IMPORTANT :

Décharger d’abord le condensateur : placer une résistance de

20 000 ohms en contact entre les bornes du condensateur et le boîtier du
condensateur.

a)

Configurer l’ohmètre à l’échelle RX 10k.

b)

Contacter les bornes du condensateur du ventilateur. La résistance
mesurée doit être basse au début puis augmente graduellement jusqu’à
l’infini.

Si la résistance du condensateur du moteur est correcte, passer à
l’étape 7.

Si la résistance mesurée pour le
condensateur est incorrecte, remplacer le
condensateur.

7.

Voir la figure 5. Contrôler la résistance du
bobinage principal du moteur : entre les
conducteurs 7 et 8 du connecteur blanc du
moteur.

Si la résistance du bobinage du moteur est
située entre 2,4 et 3,6 ohms, il doit y avoir
un circuit ouvert entre le moteur et le
module de commande électronique de la
machine. Réinstaller le câblage principal.

Si la résistance du moteur est très
supérieure à 4 ohms, remplacer le moteur
d’entraînement.

8.

On peut identifier un problème du contacteur
de la porte lors des Tests de diagnostic de la
page 2; cependant, si cela n’a pas été fait, on
peut exécuter les opérations suivantes sans
mettre la sécheuse sous tension. Brancher un
ohmmètre entre les points P6-2 (conducteur
noir) et P6-1 (conducteur noir). Lorsque la
porte est correctement fermée, on doit mesurer
une résistance de 0 à 2 ohms (circuit fermé);
sinon, remplacer le contacteur de la porte.

TEST N

o

3 Circuit chauffant

On exécute ce test lorsque l’une des situations
suivantes se manifeste :

Absence de chauffage

Impossibilité d’arrêt du chauffage

Avec ce test, on contrôle les composants du
circuit de chauffage; il s’agit des composants
suivants :

Câblage/ connexion

Relais de chauffage

Thermostat - limite
haute

Brûleur à gaz

Capteur
thermométrique

Circuit électronique
de commande de la
machine. Voir à la
page 1 l’information
sur la décharge
électrostatique.

Module de
l’interface-utilisateur

Alimentation à gaz

Absence de chauffage :

1.

Débrancher la sécheuse ou déconnecter la
source de courant électrique.

2.

Enlever le panneau de plinthe pour accéder
aux composants du système de chauffage. Voir
Dépose du panneau de plinthe, page 14. À
l’aide de la figure 6, identifier les composants.

7.

Check the resistance value of the
motor’s Main winding coil by
contacting points 7 and 8 of the white
motor connector, as shown in
figure 5.

If the resistance at the drive motor
is in the range of 2.4–3.6 ohms,
there is an open circuit between
the motor and the machine control
electronics.  Replace the main
wiring harness.

If the resistance at the drive motor
is much greater than 4 ohms,
replace the drive motor.

8.

Door Switch problems can be
uncovered in the Diagnostic Tests on
page 2; however, if this was not
done, the following can be done
without applying power to the dryer.
Connect an ohmmeter across P6-2
(black wire) and P6-1 (black wire).
With the door properly closed, the
ohmmeter should indicate a closed
circuit (0–2 ohms). If not, replace the
door switch assembly.

TEST #3 Heating Circuit

This test is performed when either of the
following situations occur:

Dryer doesn’t heat

Heat won’t shut off

This test checks the components
making up the heating circuit. The
following items are part of this system:

Harness/
connection

Heater relay

High limit
thermostat

Gas burner
assembly

Temperature
sensor

Machine control
electronics. See
ESD information,
page 1.

User interface
assembly

Gas supply

Dryer does not heat:

1.

Unplug dryer or disconnect power.

2.

Remove the toe panel to access the
thermal components. See Removing
the Toe Panel, page 14. Locate the
components using figure 6.

Thermal Components,
viewed from front.

Composants du système

de chauffage - vue de face.

Figure 6

Содержание KHGV01RSS0

Страница 1: ...mballage des circuits électroniques de la machine défaillante dans le sachet antistatique appliquer les instructions ci dessus GUIDE DE DIAGNOSTIC Avant d entreprendre un travail de réparation vérifier ce qui suit Vérifier que la prise de courant est alimentée Fusible grillé ou disjoncteur ouvert Fusible temporisé Conduit d évacuation convenablement installé et pas obstrué par charpie ou débris Ut...

Страница 2: ...lay Action Proceed to TEST 3a page 8 TESTS DE DIAGNOSTIC Ces tests permettent au technicien de contrôler tous les signaux d entrée parvenant au système de commande électronique de la machine Ces tests permettent l exécution d un contrôle global et rapide de la sécheuse avant le passage à des tests de diagnostic spécifiques TEST DE DIAGNOSTIC NO 1 FONCTIONNEMENT DES SYSTÈMES DE COMMANDE ACTIVATION ...

Страница 3: ...amme doit provoquer l émission d un signal sonore ou commander une ou plusieurs DEL voir figure 1 Diagnostic de la console à la page 2 L afficheur de temps restant estimé indiquera un code d identification du logiciel Diagnostic Capteur d humidité Identifier les deux rubans métalliques sur la paroi de droite du logement de la porte Établir un pontage entre ces deux rubans métalliques avec un doigt...

Страница 4: ...he cycle or press Pause Cancel to clear the display Refer to TEST 1 page 6 E1 TEMPERATURE SENSOR OPEN E1 flashes in the numeric display when the temperature sensing circuit is open Refer to TEST 3a page 8 E2 TEMPERATURE SENSOR SHORTED E2 flashes in the numeric display when the temperature sensing circuit is shorted Refer to TEST 3a page 8 E3 BLOWER ROTATION FAILURE If during a cycle the blower rot...

Страница 5: ...MANDES Si une nouvelle carte des circuits de commande a été installée exécuter les étapes décrites ci dessous pour sélectionner la source d énergie appropriée gaz ou électricité Mode Menu Il s agit d une opération exécutée à l usine pour l étalonnage du capteur et du circuit de régulation de la température et la configuration de la machine pour gaz ou électricité processus différents pour les prog...

Страница 6: ... terminals gas dryer Cordon d alimentation sécheuse à gaz Figure 4 Power cord to wire harness connection for gas dryer Raccordement entre cordon d alimentation et câblage de la sécheuse sécheuse à gaz Figure 3 Disconnect white motor connector Débrancher le connec teur blanc du moteur Figure 5 1 Débrancher la sécheuse ou déconnecter la source de courant électrique 2 Accéder au module de commande él...

Страница 7: ... diagnostic de la page 2 cependant si cela n a pas été fait on peut exécuter les opérations suivantes sans mettre la sécheuse sous tension Brancher un ohmmètre entre les points P6 2 conducteur noir et P6 1 conducteur noir Lorsque la porte est correctement fermée on doit mesurer une résistance de 0 à 2 ohms circuit fermé sinon remplacer le contacteur de la porte TEST No 3 Circuit chauffant On exécu...

Страница 8: ...Temperature Sensor The machine control electronics monitors the exhaust tempera ture using the temperature sen sor and cycles the heater relay on and off to maintain the de sired temperature Begin with an empty dryer and a clean lint screen 1 Plug in dryer or reconnect power 2 Set the following configuration Door must be firmly closed Select Timed Dry cycle Press Cycle End Tone and select Loud Pre...

Страница 9: ...ur thermométrique TEST No 3b Coupe circuit pour température de décharge excessive réarmement manuel Débrancher la sécheuse ou déconnecter la source de courant électrique 2 Accéder au module de commande électronique de la machine Voir la page 12 Modules électroniques accès et dépose Mesurer la résistance entre les points P3 3 et P3 4 Si la résistance mesurée entre P3 3 et P3 4 est de 1 à 6 ohms rem...

Страница 10: ...e des circuits rechercher des débris qui pourraient former un pontage entre ces deux broches S il n y a aucun débris remplacer le module de commande électronique 6 Débrancher la sécheuse ou déconnecter la source de courant électrique 7 Accéder au capteur d humidité ôter les deux vis puis débrancher le connecteur du capteur d humidité 8 Mesurer la résistance entre les broches du capteur d humidité ...

Страница 11: ...e de l interface utilisateur TEST No 6 Contacteur de la porte Accéder au mode de Test de diagnostic no 1 Voir page 2 L apparition d un code alphanumérique sur l afficheur Révision version du logiciel porte fermée GAS porte ouverte etc confirme le bon fonctionnement Si l une des conditions ci dessus n est pas réalisée ou si l appareil affiche GAS quand la porte est fermée contrôler le branchement d...

Страница 12: ...ce utilisateur Patte de retenue Disconnect cables to remove user interface assembly from console Débrancher les câbles pour retirer l interface utilisateur de la console Figure 9 MODULES ÉLECTRONIQUES ACCÈS ET DÉPOSE Il y a deux modules électroniques le module de l interface utilisateur et le module de commande électronique de la machine Voir figure 7 1 Débrancher la sécheuse ou déconnecter la sou...

Страница 13: ... terminals See figure 13 c Unlatch and disconnect the 4 pin harness connector from the temperature sensor connector d Disconnect the 4 pin sensor connector from the mounting bracket e Remove the front clip from the temperature sensor To do this hold the clip with a pair of pliers and twist the sensor with your fingers while pushing it out of the clip 7 To remove the lint drawer switch a Unlatch an...

Страница 14: ...contacteur et extraire le contacteur à travers l ouverture dans le logement 8 Dépose du moteur du ventilateur a Enlever le logement du moteur du ventilateur et le couvercle du logement exécuter les étapes 7a à 7e b Ôter les quatre écrous de 7 mm 3 8 po les rondelles freins et les rondelles plates du logement du moteur du ventilateur Séparer le couvercle supérieur du logement du moteur placer celui...

Страница 15: ...E VITESSE RET SHIELD DRUM LIGHT OUTPUT CAPTEUR DU MOTEUR DU VENTILATEUR LAMPE TAMBOUR BK BL N BL R N R N N CONTACTEUR CAPTEUR MAGNÉTIQUE ROTATION DU TAMBOUR CAPTEUR DE RÉGULATION DE LA TEMPÉRATURE DE DÉCHARGE N N N N N N N N BL R MAR MAR GRIS GRIS N JA JA R SLV R ARG BK N O N COM N O W BL NC R BU CL N BK N BK N BL VE JA 16 µF CONDENSATEUR VE JA BL N MAR BU VE JA N BL VE JA N N N N N MODULE DE COMM...

Страница 16: ...E FOLLOWING U S PATENTS LOGICIEL ASSUJETTI AUX DROITS D AUTEUR FABRIQUÉ SOUS UN OU PLUSIEURS DES BREVETS SUIVANTS DES ÉTATS UNIS 4 669 200 4 700 495 4 754 556 4 840 285 4 865 366 4 899 464 4 908 959 4 989 347 5 066 050 5 560 120 5 809 828 6 020 698 6 047 486 6 199 300 6 446 357 6 597 144 6 604 298 6 685 241 6 732 447 6 784 673 6 819 255 D314 261 D314 262 D457 991 D457 992 D495 453 Black Noir Blue ...

Отзывы: