4-4
Electrical Shock Hazard
Connect green ground wire to ground
screw.
Failure to do so can result in death or
electrical shock.
WARNING
10.
To remove the cutoff switch:
a) Remove the two wire connectors from
the switch terminals.
b) Push in on the two locking arms and
push the switch out of the cutout.
IMPORTANT REASSEMBLY NOTE:
Be sure
to reconnect the green ground wire from the
AC receptacle to the component cover bracket.
Locking
Arm
Cutoff Switch
9.
To remove the AC receptacle:
a) Cut the black and white receptacle
wires at the indicated locations shown
below.
b) Press in on the locking spring, and push
the receptacle out of the component
cover.
c) Remove the screw from the eyelet at
the end of the green ground wire and
remove the wire from the component
cover bracket.
AC Receptacle
Locking Spring
Cut Receptacle
Wires Here
d) Splice the AC receptacle wires to the
wiring harness using two twist-on wire
nuts (see steps 6d and 6e on page 4-2
for the procedure).
Green Ground Wire
2 Wire Connectors