background image

3

INSTALLATION REQUIREMENTS

TOOLS AND PARTS

Gather the required tools and parts before starting installation.

Tools needed:

Flat-blade screwdriver

#2 Phillips screwdriver

Wire stripper (direct wire 

installations)

Channel locks

Adjustable wrench that 

opens to 1" (25 mm)  or 

hex-head socket wrench 

1/4" and 5/16" nut driver 

(recommended)

Utility knife 

Tape measure

 Level

Pliers

Leveling legs (4)

Parts package is located in dryer drum. Check that all parts  

are included.

NOTE: 

Do not use leveling legs supplied with dryer if installing 

with a pedestal or a stack kit.

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

 

A UL Listed 30 A power supply cord, rated 120/240 V 

minimum. The cord should be type SRD or SRDT and  

be at least 4 ft. (1.22 m) long. The wires that connect to  

the dryer must end in ring terminals or spade terminals  

with upturned ends.

 

A UL Listed strain relief.

Additional Accessories: 

(Not supplied with dryer) 

Refer to your Use and Care Guide for information about 

accessories available for your dryer.

Parts supplied: 

6' (1.82 m) drain 

hose with couplers

Cable ties (2)

Содержание HYBRIDCARE YWHD560CHW0

Страница 1: ...utillage et pièces 22 EXIGENCES D EMPLACEMENT 23 SYSTÈME DE VIDANGE 24 SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À L ALIMENTATION ÉLECTRIQUE CANADA SEULEMENT 25 INSTALLATION DES PIEDS DE NIVELLEMENT 26 CONNEXION DU TUYAU DE SORTIE 26 RÉGLAGE DE L APLOMB DE LA SÉCHEUSE 27 ACHEVER L INSTALLATION LISTE DE VÉRIFICATION 28 INVERSION DE LA PORTE FACULTATIF 28 DÉPANNAGE COUVERTURE ARRIÈRE INSTALLATION NOTES Date ...

Страница 2: ...AFETY Certain internal parts are intentionally not grounded and may present a risk of electric shock only during servicing Service Personnel Do not contact the thermostat bracket while the appliance is energized ...

Страница 3: ...t use leveling legs supplied with dryer if installing with a pedestal or a stack kit If using a power supply cord Use a UL Listed power supply cord kit marked for use with clothes dryers The kit should contain A UL Listed 30 A power supply cord rated 120 240 V minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals...

Страница 4: ...llation place dryer at least 18 460 mm above floor If using a pedestal you will need 18 460 mm to bottom of dryer The dryer must not be installed or stored in an area where it will be exposed to water and or weather IMPORTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 40 F 4 C Lower temperatures may cause dryer to not shut off at end of...

Страница 5: ... HUD Part 280 or Standard CAN CSA Z240 MH 18 min 457 mm 1 25 mm 5 127 mm 24 in 2 min 155 cm2 48 in 2 min 310 cm2 3 76 mm 3 76 mm 1 25 mm NOTE 0 0 mm spacing is allowed behind dryer providing drain hose is not kinked or pinched DRAIN SYSTEM Minimum diameter for a standpipe drain 2 51 mm Minimum carry away capacity 17 gal 64 L per minute A 1 4 6 mm diameter to 1 25 mm diameter Standpipe Adapter Kit ...

Страница 6: ...at least 4 ft 1 22 m long must have four 10 gauge copper wires and match a 4 wire receptacle of NEMA Type 14 30R The ground wire ground conductor may be either green or bare The neutral conductor must be identified by a white cover Then choose a 3 wire power supply cord with ring or spade terminals and UL Listed strain relief The 3 wire power supply cord at least 4 ft 1 22 m long must have three 1...

Страница 7: ...ING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician To supply the required 4 w...

Страница 8: ...dryer until it is close to its final location ELECTRICAL INSTALLATION U S A ONLY Remove hold down screw and terminal block cover 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Go to Power Supply Cord Connection 3 wire direct connection Go to Direct Wire Connection 4 wire direct connection Go to Direct Wire Connection Power supply cord 3 wire receptacle NEM...

Страница 9: ... for mobile homes and where local codes do not permit the use of 3 wire connections 4 wire receptacle NEMA type 14 30R 4 prong plug Spade terminals with upturned ends Ring terminals 2 Attach power supply cord to strain relief Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fi...

Страница 10: ...e F green or bare of power supply cord under green external ground conductor screw A Tighten screw 3 wire receptacle NEMA type 10 30R 3 prong plug Spade terminals with upturned ends Ring terminals 4 Connect remaining wires 1 Remove center screw B Connect remaining wires under outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secur...

Страница 11: ...strain relief UL marking on strain relief Put the threaded section of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads and tighten securely Fire Hazard Use 10 gauge copper wire Use a UL listed strain relief Disconnect power before making electrical connections Co...

Страница 12: ...27 mm Cut 11 2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks 3 wire direct connection Go to 3 Wire Direct Wire Connection 4 wire direct connection Go to 4 Wire Direct Wire Connection If your wiring looks like this 4 Connect ground wire F A Connect ground wire green or bare F of direct wire cable under green external ground conductor screw A Tighten screw...

Страница 13: ... ground conductor to neutral wire 3 Connect neutral wire C B Place hooked end of neutral wire white or center C of direct wire cable under center terminal block screw B hook facing right Squeeze hooked end together Tighten screw 4 Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tigh...

Страница 14: ...anel Secure cover with hold down screw Now go to Connect Outlet Hose 4 Connect external ground wire G A CONNECT OUTLET HOSE 1 Attach hose Attach the goose neck fitting of the provided 6 ft 1 82 m drain hose to the drain valve at the bottom of dryer back panel Screw on coupling by hand until it is seated on valve connector 2 Tighten coupling Using channel locks tighten the coupling an additional tw...

Страница 15: ... dryer is greater than 1 25 mm water could run out from front of filter 2 Adjust leveling legs If dryer is not level prop up using a wood block use a wrench to adjust legs up or down and check again for levelness Once dryer is level make sure all four legs are snug against the floor and dryer does not rock 3 Plug into a grounded 3 prong outlet 4 Check for leaks While running the first cycle check ...

Страница 16: ...art check the following Controls are set to a running or On position Start button has been pressed firmly Dryer is plugged into an outlet and or electrical supply Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer automatically runs an installation diagnostic routine at the start of its first cycle NOTE You may notice an odor when dryer is first h...

Страница 17: ...r peel the film from the dryer door before proceeding Using a T25 screwdriver remove the four screws securing the door hinge to the dryer and lift the door up and out to remove Place the door on a soft towel or other non scratch surface ALL DOORS 4 Remove inner door from outer door Position the door with the inside of the door facing up Using a Phillips screwdriver remove the 10 screws securing th...

Страница 18: ... is at the bottom Using a T25 screwdriver remove the four screws securing the latch plate in place 8 Reinstall hinge assembly on opposite side Flip over the inner door to the left Using a T20 screwdriver reinstall the hinge assembly on the opposite side from which it was removed DOORS WITH LCD SCREEN 9 Remove rotating assembly Lift off inner door assembly Using a Phillips screwdriver remove the tw...

Страница 19: ...f rotating assembly see Step 12 Press tubing into indents 12 Reinstall inner door assembly Position the door with the inside of the door facing up Using a Phillips screwdriver reinstall the 10 screws removed earlier securing the inner door to the outer door 13 Reinstall door on dryer Doors with electrical wiring Pull the wire through the front panel opening before reinstalling the door Insert the ...

Страница 20: ...ur website and reference Frequently Asked Questions to possibly avoid the cost of a service call 14 Reconnect wiring Plug in wire Using a Phillips screwdriver secure the rotating assembly to the hinge with the screw removed earlier DOORS WITH LCD SCREEN 6 18 ...