LOCATION REQUIREMENTS

Check codes requirements. Some codes limit, or do not permit, 

installing dryer in garages, closets, mobile homes, or sleeping 

quarters. Contact your local building inspector.

You will need:

 

A separate 30 A circuit.

 

If using a power supply cord, a grounded electrical outlet  

located within 2 ft. (610 mm) of either side of dryer. See 

“Electrical Requirements.”

 

Floor must support dryer weight of 200 lbs. (90.7 kg). Also 

consider weight of companion appliance.

 

Level floor with maximum slope of 1" (25 mm) under entire 

dryer. If forward slope is greater than 1" (25 mm), water could 

run out from front of filter. Install Extended Dryer Feet Kit, Part 

Number 279810. If not level, clothes may not tumble properly 

and automatic sensor cycles may not operate correctly.

 

For garage installation, place dryer at least 18" (460 mm)  

above floor. If using a pedestal, you will need 18" (460 mm)  

to bottom of dryer.

 

The dryer must not be installed or stored in an area where it  

will be exposed to water and/or weather.

IMPORTANT:

 Do not operate, install, or store dryer where  

it will be exposed to water, weather, or at temperatures below  

40°F (4°C). Lower temperatures may cause dryer to not  

shut off at end of automatic sensor cycles, resulting in longer  

drying times.

DRYER DIMENSIONS

27"

(686 mm)

38

3

/

4

" Min.

(984 mm)

39" Max.

(990 mm)

Front view:

Side view:

51    " min.

(1314 mm)

31    " min.

(806 mm)

Back view:

13

1

/

2

"

(343 mm)

6

1

/

2

"

(165 mm)

6

1

/

2

"

(165 mm)

29

7

/

8

"*

(759 mm)

NOTE:

 Allow 

clearance behind 

dryer for proper 

drain hose routing 

and cooling fan 

ventilation. Push 

dryer back as 

far as possible 

and make sure 

drain hose is not 

crushed or kinked.

*Approx. measurement

 

Water 

drain

Cooling 

fan

IMPORTANT:

 Do not block cooling fan, as your dryer may not 

operate properly.

Power cord/

cable

54

1

/

2

(1378 mm)

31" 

(787 mm)

5

3

/

4

(146 mm)

Содержание HYBRIDCARE YWHD560CHW0

Страница 1: ...utillage et pièces 22 EXIGENCES D EMPLACEMENT 23 SYSTÈME DE VIDANGE 24 SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À L ALIMENTATION ÉLECTRIQUE CANADA SEULEMENT 25 INSTALLATION DES PIEDS DE NIVELLEMENT 26 CONNEXION DU TUYAU DE SORTIE 26 RÉGLAGE DE L APLOMB DE LA SÉCHEUSE 27 ACHEVER L INSTALLATION LISTE DE VÉRIFICATION 28 INVERSION DE LA PORTE FACULTATIF 28 DÉPANNAGE COUVERTURE ARRIÈRE INSTALLATION NOTES Date ...

Страница 2: ...AFETY Certain internal parts are intentionally not grounded and may present a risk of electric shock only during servicing Service Personnel Do not contact the thermostat bracket while the appliance is energized ...

Страница 3: ...t use leveling legs supplied with dryer if installing with a pedestal or a stack kit If using a power supply cord Use a UL Listed power supply cord kit marked for use with clothes dryers The kit should contain A UL Listed 30 A power supply cord rated 120 240 V minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals...

Страница 4: ...llation place dryer at least 18 460 mm above floor If using a pedestal you will need 18 460 mm to bottom of dryer The dryer must not be installed or stored in an area where it will be exposed to water and or weather IMPORTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 40 F 4 C Lower temperatures may cause dryer to not shut off at end of...

Страница 5: ... HUD Part 280 or Standard CAN CSA Z240 MH 18 min 457 mm 1 25 mm 5 127 mm 24 in 2 min 155 cm2 48 in 2 min 310 cm2 3 76 mm 3 76 mm 1 25 mm NOTE 0 0 mm spacing is allowed behind dryer providing drain hose is not kinked or pinched DRAIN SYSTEM Minimum diameter for a standpipe drain 2 51 mm Minimum carry away capacity 17 gal 64 L per minute A 1 4 6 mm diameter to 1 25 mm diameter Standpipe Adapter Kit ...

Страница 6: ...at least 4 ft 1 22 m long must have four 10 gauge copper wires and match a 4 wire receptacle of NEMA Type 14 30R The ground wire ground conductor may be either green or bare The neutral conductor must be identified by a white cover Then choose a 3 wire power supply cord with ring or spade terminals and UL Listed strain relief The 3 wire power supply cord at least 4 ft 1 22 m long must have three 1...

Страница 7: ...ING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician To supply the required 4 w...

Страница 8: ...dryer until it is close to its final location ELECTRICAL INSTALLATION U S A ONLY Remove hold down screw and terminal block cover 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Go to Power Supply Cord Connection 3 wire direct connection Go to Direct Wire Connection 4 wire direct connection Go to Direct Wire Connection Power supply cord 3 wire receptacle NEM...

Страница 9: ... for mobile homes and where local codes do not permit the use of 3 wire connections 4 wire receptacle NEMA type 14 30R 4 prong plug Spade terminals with upturned ends Ring terminals 2 Attach power supply cord to strain relief Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fi...

Страница 10: ...e F green or bare of power supply cord under green external ground conductor screw A Tighten screw 3 wire receptacle NEMA type 10 30R 3 prong plug Spade terminals with upturned ends Ring terminals 4 Connect remaining wires 1 Remove center screw B Connect remaining wires under outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secur...

Страница 11: ...strain relief UL marking on strain relief Put the threaded section of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads and tighten securely Fire Hazard Use 10 gauge copper wire Use a UL listed strain relief Disconnect power before making electrical connections Co...

Страница 12: ...27 mm Cut 11 2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks 3 wire direct connection Go to 3 Wire Direct Wire Connection 4 wire direct connection Go to 4 Wire Direct Wire Connection If your wiring looks like this 4 Connect ground wire F A Connect ground wire green or bare F of direct wire cable under green external ground conductor screw A Tighten screw...

Страница 13: ... ground conductor to neutral wire 3 Connect neutral wire C B Place hooked end of neutral wire white or center C of direct wire cable under center terminal block screw B hook facing right Squeeze hooked end together Tighten screw 4 Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tigh...

Страница 14: ...anel Secure cover with hold down screw Now go to Connect Outlet Hose 4 Connect external ground wire G A CONNECT OUTLET HOSE 1 Attach hose Attach the goose neck fitting of the provided 6 ft 1 82 m drain hose to the drain valve at the bottom of dryer back panel Screw on coupling by hand until it is seated on valve connector 2 Tighten coupling Using channel locks tighten the coupling an additional tw...

Страница 15: ... dryer is greater than 1 25 mm water could run out from front of filter 2 Adjust leveling legs If dryer is not level prop up using a wood block use a wrench to adjust legs up or down and check again for levelness Once dryer is level make sure all four legs are snug against the floor and dryer does not rock 3 Plug into a grounded 3 prong outlet 4 Check for leaks While running the first cycle check ...

Страница 16: ...art check the following Controls are set to a running or On position Start button has been pressed firmly Dryer is plugged into an outlet and or electrical supply Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer automatically runs an installation diagnostic routine at the start of its first cycle NOTE You may notice an odor when dryer is first h...

Страница 17: ...r peel the film from the dryer door before proceeding Using a T25 screwdriver remove the four screws securing the door hinge to the dryer and lift the door up and out to remove Place the door on a soft towel or other non scratch surface ALL DOORS 4 Remove inner door from outer door Position the door with the inside of the door facing up Using a Phillips screwdriver remove the 10 screws securing th...

Страница 18: ... is at the bottom Using a T25 screwdriver remove the four screws securing the latch plate in place 8 Reinstall hinge assembly on opposite side Flip over the inner door to the left Using a T20 screwdriver reinstall the hinge assembly on the opposite side from which it was removed DOORS WITH LCD SCREEN 9 Remove rotating assembly Lift off inner door assembly Using a Phillips screwdriver remove the tw...

Страница 19: ...f rotating assembly see Step 12 Press tubing into indents 12 Reinstall inner door assembly Position the door with the inside of the door facing up Using a Phillips screwdriver reinstall the 10 screws removed earlier securing the inner door to the outer door 13 Reinstall door on dryer Doors with electrical wiring Pull the wire through the front panel opening before reinstalling the door Insert the ...

Страница 20: ...ur website and reference Frequently Asked Questions to possibly avoid the cost of a service call 14 Reconnect wiring Plug in wire Using a Phillips screwdriver secure the rotating assembly to the hinge with the screw removed earlier DOORS WITH LCD SCREEN 6 18 ...

Отзывы: