5-2
COOLING FAN MOTOR
Cooling Fan
Motor
Terminals
NOTES:
1.
FAN RATING IS 120 VAC, 50/60 HZ,
2.5-WATTS.
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
WARNING
Test Procedure
Refer to page 4-16 for the location of the cool-
ing fan motor and the procedure for servicing
it.
To test the cooling fan motor windings, perform
the following steps:
1.
Use an ohmmeter and set the range switch
to R x 1.
2.
With no power applied, touch the leads of
the ohmmeter to the terminals of the fan
motor (you do not have to remove the
wires from the terminals). You should ob-
tain a reading of between 55
Ω
and 80
Ω
.
If the reading is not within the range shown,
the motor is defective and should be replaced.
OVEN LIGHT SWITCH
Oven Light
Switch
3 Terminals
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
WARNING
Test Procedure
Refer to page 4-14 for the location of the oven
light switch and the procedure for servicing it.
To test the oven light switch, perform the fol-
lowing steps:
1.
Use an ohmmeter and set the range switch
to R x 1.
2.
With no power applied, remove the wires
from the switch terminals.
3.
Touch the leads of the ohmmeter to the
following terminal wires of the switch.
NOTE: A closed circuit = continuity (0
Ω
),
an open circuit = infinite (
∞
):
Black & Red:
Door Closed = infinite.
Door Open = continuity.
Black & Yellow:
Door Closed = continuity.
Door Open = infinite.
If the above results are not obtained, the switch
is defective and should be replaced.
Yellow
(Narrow Terminal)
Red
(Wide Terminal)
Black
(Wide Terminal)