2-4
Explosion Hazard
Shut off gas supply line valve.
Make all conversions before turning gas
supply valve back on.
Failure to follow these instructions could
result in fire, explosion, or other injury.
WARNING
CONVERTING THE RANGE FOR USE WITH L.P. GAS
Gas conversion must be done by a quali-
fied installer. Examples of a qualified in-
staller includes licensed heating personnel,
authorized gas company personnel, and au-
thorized service personnel.
L.P. gas must not be used unless the L.P. con-
version has been made using the kit that is
included with this range. See the “Gas Supply
Requirements” starting on page 2-1.
3.
Carefully pry the protective plastic cap
and washer off the threaded metal cap.
4.
Position the plastic cap so that L.P. is
displayed facing up, then install the cap
onto the threaded end of the metal cap.
5.
Reinstall the cap assembly to the pres-
sure regulator and tighten it firmly. Do not
overtighten the cap.
CONVERTING THE
PRESSURE REGULATOR
1.
Remove the storage drawer, oven racks,
and the oven bottom from the range.
NOTE: The pressure regulator is located in the
lower left rear corner of the storage drawer
area.
2.
Use a wrench and unscrew the plastic-
coated hex nut cap assembly from the
pressure regulator. Do not remove the
regulator.
LP
NAT
Pull open
cap assembly
Do Not remove this protective
cap except for conversion
NAT
L.P.