4-21
REMOVING THE HIGH-VOLTAGE
CAPACITOR AND THE MAGNETRON
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug microwave oven or disconnect
power.
2. Remove the microwave oven from its
mounting location (see page 2-4 for the
procedure and reverse the procedure).
3. Remove the cabinet from the oven (see
page 4-4 for the procedure).
4. Remove the cooling fan motor from the
oven (see page 4-19 for the procedure).
5. Unclip the wiring from the front of the fan
shroud.
6. Remove the two top, front, and bottom
screws (6 total) from the fan shroud.
High-Voltage
Capacitor
Magnetron
Top Fan Shroud Screws
Front Fan Shroud Screws
Bottom Fan Shroud Screws
Continued on the next page.