4-12
SOLUTION
Control knob will not turn.
Press in on the knob before turning.
If knob is still hard to turn, replace the
gas valve.
The self-clean cycle will not operate.
A delay start time has been pro-
grammed.
The cooling fan is not running.
Wait for the start time to be reached.
Check the cooling fan wiring.
Test the control panel shutdown switch.
Replace the motor.
“PF” shows on the display.
There has been a power failure.
Reset the clock.
A failure code (E3, F1, etc.) is show-
ing on the display.
Press the CANCEL/OFF keypad.
If the code does not disappear, refer
to page 4-14, and identify the cause of
the error message to help you correct
the problem.
The keypads do not operate.
The Control Lock has been set.
Press and hold the Control Lock key-
pad for 5-seconds to unlock the key-
pads.
The range is not properly grounded.
POSSIBLE CAUSE
PROBLEM