12
Base Grille Water Filtration System
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Model WF-NL240V/NL240V Capacity 240 Gallons (908 Liters)
Model WF-L400V/L400V Capacity 400 Gallons (1514 Liters)
■
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■
Model WF-NL240V Change cartridge at least every 6-9
months. Use replacement cartridge NL240V, part #4396509.
2004 suggested retail price of $35.99 U.S.A./$59.95 Canada.
Prices are subject to change without notice.
■
Model WF-L400V The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge L400V, part
#4396509. 2004 suggested retail price of $35.99 U.S.A./
$59.95 Canada. Prices are subject to change without notice.
■
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before
or after the system.
■
Refer to the front cover or “Assistance or Service” section for
the Manufacturer’s name, address and telephone number.
■
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Chlorine Taste/Odor
Particulate Class II
*
≥
50%
≥
85%
2.0 mg/L
833,333/mL
2.0 mg/L ± 10%
At least 10,000
particles/ml
0.03 mg/L
100,000/mL**
0.02 mg/L
40,667/mL
98.5%
88.0%
99.0%
95.1%
504232-01
507163-02
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01mg/L
0.01mg/L
0.16 mg/L***
0.15 mg/L***
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.001 mg/L
0.001 mg/L
0.001 mg/L
99.35%
99.31%
99.35%
99.31%
507610-01
507611-01
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.003 mg/L
0.002 mg/L
0.0062 mg/L
0.0061 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0003 mg/L
0.0009 mg/L
0.00023 mg/L
0.00052 mg/L
95.2%
85.2%
96.8%
91.8%
507160-02
507161-02
Benzene
0.005 mg/L
0.014 mg/L
0.015 ± 10%
0.0005 mg/L
0.0005 mg/L
96.4%
96.4%
507169-02
p-dichlorobenzene
0.075 mg/L
0.219 mg/L
0.225 ± 10%
0.0005 mg/L
0.0005 mg/L
99.77%
99.77%
507172-02
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 ± 10%
0.0012 mg/L
0.001 mg/L
91.43%
92.6%
507171-02
Carbofuran
0.04 mg/L
0.077 mg/L
0.080 ± 10%
0.031 mg/L
0.0064 mg/L
59.7 %
91.6%
507168-02
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirement
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Chlorine Taste/Odor
Particulate Class II
*
≥
50%
≥
85%
2.0 mg/L
833,333/mL
2.0 mg/L ± 10%
At least 10,000
particles/ml
0.03 mg/L
100,000/mL**
0.02 mg/L
40,667/mL
98.5%
90.9%
99.0%
95.1%
504232-01
507163-02
Contaminant
Reduction
NSF Reduction
Requirement
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01mg/L
0.01mg/L
0.16 mg/L***
0.15 mg/L***
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.001 mg/L
0.001 mg/L
0.001 mg/L
99.35%
99.31%
99.35%
99.31%
507610-01
507611-01
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.003 mg/L
0.002 mg/L
0.0062 mg/L
0.0061 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0003 mg/L
0.0009 mg/L
0.00023 mg/L
0.00052 mg/L
95.2%
85.2%
96.22%
91.57%
507160-02
507161-02
Benzene
0.005 mg/L
0.014
0.015 ± 10%
0.005 mg/L
0.0005
96.4%
96.4%
507169-02
p-dichlorobenzene
0.075 mg/L
0.219
0.225 ± 10%
0.0005 mg/L
0.0005
99.77%
99.77%
507172-02
Toxaphene
0.003 mg/L
0.014
0.015 ± 10%
0.0012 mg/L
0.001
91.43%
92.86%
507171-02
Carbofuran
0.04 mg/L
0.0768
0.080 ± 10%
0.031 mg/L
0.0057
59.7 %
92.5%
507168-02
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine, Taste and Odor, Particulate Class II*;
and against ANSI/NSF Standard 53 for the reduction of Lead,
Mercury, Benzene, Toxaphene, p-dichlorobenzene, and Carbofuran.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)
0.5 gpm (1.9 L/min.) @ 60 psi.
*
**
***
Class II particle size: >1 to <5
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.