4-7
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
NOTE:
Sharp edges may be present.
1.
Disconnect the power to the drying cabi-
net.
2.
Remove the component panel (see page
4-2 for the procedure).
3.
Remove the two mounting screws and
lockwasher from the shield and remove
the shield from the component panel.
Door Switch
PTS Switch
Locking Arms
4.
To remove the push-to-start (PTS)
switch or the door switch:
a) Disconnect the wires from the termi-
nals.
b) Press in on the locking arms and push
the switch out of the front panel cutout.
REMOVING THE PUSH-TO-START & DOOR SWITCHES
Shield
Screw &
Lockwasher
Screw