4-3
4.
To remove the heater:
a) Remove the two Torx screws from the
high limit thermostat.
b) Disconnect the three wires from the
heater terminals.
Torx
Screw
(1 of 2)
Heater
Wire
c) Turn the component shelf over and re-
move the four screws from the front and
rear heater brackets.
Heater
Viewed From Bottom Of Unit
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
REMOVING THE HIGH LIMIT THERMOSTAT AND THE HEATER
NOTE:
Sharp edges may be present.
1.
Disconnect the power to the drying cabi-
net.
2.
Remove the component panel (see page
4-2 for the procedure).
3.
To remove the high limit thermostat:
a) Disconnect the wires going to the
heater and thermostat terminals.
b) Remove the two Torx screws.
Heater Bracket Screws
3 Heater Wires
Thermostat
Wire
High Limit Thermostat
High Limit Thermostat