USE OF THE INDUCTION COOKING ZONE
Control panel
Control panel graphics shown in these instructions might not match exactly the graphics of your hob. Button
functions are the same for all hob models.
Switching the hob ON/OFF
To switch the hob on, press the
button for approx. 2 seconds until the cooking zone displays light up. To switch off,
press the same button until the displays switch off.
If the hob has been in use, the residual heat indicator “H” remains lit until the induction cooking zone has cooled down.
The hob automatically switches off if no function is selected within 10 seconds of switching on.
Switching on and adjusting cooking zone
After switching on the hob and positioning the pot on the chosen induction cooking zone, adjust the heat setting using
the . After pressing the + button, the display shows level 0.
The cooking zone has different heat settings that can be adjusted using the b/-, which go from “1”: min. heat
setting to “9”: max. heat setting. The fast boil function (Booster) is shown on the display with the letter “P”.
Fast boil function (Booster)
This function makes it possible to exploit the hob's maximum power (for example to bring water to the boil very quickly).
To select this function, press the button “+” until “P” appears on the display or, after switching the hob on, press the “-”
button. In this case too, “P” appears on the display. After 10 minutes' use of the booster function, the appliance
automatically sets the zone to level 9.
Switching off cooking zone
Select the cooking zone to be switched off, pressing the “+” or “-” button (a dot at the bottom right of the power level is
displayed).
Press the key “-” to set the level to “0”.
The cooking zone can also be switched off by pressing keys “+” and “-” at the same time. The cooking zone is deactivated
and the residual heat indicator “H” appears
Key lock
This function locks the hob controls to prevent accidental switching on. To activate the key lock function, switch on the
hob then press and hold the
button for three seconds: an acoustic signal and a luminous indicator under the key
symbol signal activation. The control panel is locked with the exception of the OFF function. To unlock the controls, repeat
the key lock activation procedure. The illuminated dot switches off and the hob is active again.
The presence of cleaning water, liquid spilled from pots or any objects resting on the button below the symbol can
accidentally activate or deactivate the key lock function.
Key lock
Chose a cooking zone
On/Off
Timer
Heat set indicator
Selected cooking
zone indicator
Buttons
Timer display
Timer
The timer can be used to set a max. cooking time of 99 minutes (1 hour and 39 minutes).
Set the desired time using buttons "+" and "-" of the timer function (see figure above). A few seconds after
the button is pressed, the timer begins the countdown (the luminous dot of the selected cooking zone
starts flashing). Once the set time has elapsed, an acoustic signal sounds and the cooking zone switches
off automatically.
To deactivate the timer, press the button “-” until the display shows “0:0” or press the buttons “+” and “-” of the timer at
the same time.
Minute minder
The minute minder can only be used when the hob is not in use and allows a maximum setting of 99 min.
Press the button “+” below the timer indicators: the display shows the minutes for setting.
Select the time desired using the b and -.
After a few seconds the minute minder starts to count down. Once the set time has elapsed an acoustic signal sounds.
IMPORTANT!
The minute minder function can only be used when the hob is switched off; if it is then switched on, the
minute minder countdown is automatically cancelled.
Control panel indicators.
Residual heat indicator.
The hob is fitted with a residual heat indicator for the induction cooking zone.
If the display shows
, the cooking zone is still hot. If the residual heat indicator of a given cooking zone is lit, that zone
can be used, for example, to keep a dish warm or to melt butter.
When the cooking zone cools down, the display switches off.
Incorrect or missing pot indicator.
The hob features an automatic pot detection system. If no pot is detected, the display with the cooking zone power
level indicator flashes. Make sure the pot is correctly positioned and that it has the characteristics given in the
section “Before Use”.
If no pot is detected after 60 seconds, the hob switches off.
RELEVANT NATIONAL REGULATIONS
Connection to gas supply
Before connecting the appliance, make sure that the gas supply system complies with standards
UNI-CIG 7129
and
UNI
CIG 7131
.
Gas connection
The connection to the mains gas network or gas cylinder must be made using a rigid copper or steel pipe with fittings
complying with standards
UNI-CIG 7129
, or using a continuous-surface stainless steel hose complying with standards
UNI
EN 148001
.
The maximum length of the hose is 2 m.
The pressure control valves to be used must comply with the
UNI EN 16129
standard for gas cylinders and the
UNI EN 88-1
standard for piped methane gas.
IT