8
P5
Machine type
1 = brief, continuous wash (maximum 10’)
2 = brief, medium, long, continuous wash (maximum 10’)
3 = brief and medium wash set to 1
4 = break tank, medium, long and continuous wash
with this configuration the cold rinse option must be set to “0”
5 = with three wash cycles without break tank for top-loading
6 = with three wash cycles with break tank for top-loading
P6
Drain with overflow option
YES/NO
0 NO
P7
Cold rinse option
YES/NO
0 NO
P8
Regeneration option
YES/NO
0 NO
P9
Maximum water load duration
1-10’
10
To access the factory menu the following procedure must be followed:
1) Shut the machine off with the
button
2) Within 6 seconds of machine shutdown press the
button 7 times
At the end of the 6 seconds, the message “ P0” will appear on the screen.
3) Select the parameter to modify with the
button
4) Press the
button to view the selected parameter on the display
5) Modify the parameter with the
button
6) Confirm the modification with the
button
7) Select, in the same way, other parameters to be modified and modify them as described above
8) After having set all of the machine’s parameters, press the
button to exit.
7
SCREEN DISPLAYED ANOMALIES
The machine is capable of signaling a series of malfunctions on the display.
If the problem persists after having turned the machine off and then on again, act as indicated below:
E1
Boiler sensor malfunction
Substitute
E2
Tank sensor malfunction
Substitute
E3
Water loading timeout ( the water loading duration
has exceeded the time set in P9 )
Electrovalve inspection – Verify that the water
faucet is open
E6
Draining anomaly. At the end of the draining phase
the CPU still detects water in the Tank. This may
be due to:
Drain pump malfunction
Drain tube blockage
Tank Pressostat malfunction
Drain cycle time ( P0 ) set too low
E7
30 minute Tank timeout
Inspect the Tank and boiler thermostats
Check for inverted sensors
E8
15 minute boiler timeout
Inspect the Tank and boiler thermostats
Check for inverted sensors