4
2
Technical characteristics
AGB672
AGB669
AGB666
AGB670
AGB664
Voltage
V
400V/3+N
230V/1
400V/3+N
230V/1
400V/3+N
230V/1
Frequenza
Hz 50 50 50
Total power
kW 6,75 7,1 10,75
Boiler element power
kW 6
6 10
Tank element power
kW 3
3 3
Wash pump power
kW 0,75 1,1 0,75
Water supply pressure
kPa 200-400 200-400 200-400
Water supply temperature
°C
50 – 60
50 – 60
15 – 30
Water supply hardness
°dF
7 – 12
7 – 12
7 – 12
Rinse cycle water consumption
l 3,5 3,5 3,5
Boiler capacity
l 9 9 12
Tank capacity
l 28 35 28
Standard cycle duration with water supply at 50°C
s 60/120/180/C
60/120/180/C 60/120/180/C
Noise level
dB(A) 67
67
67
Protection rating
IPX 4
4
4
Net weight
kg 115 123 118
Power cable type
◄
HAR
►
H05VV-F H05VV-F H05VV-F
Electrical Scheme – voltage regulation
R
S
T
R
S
T
400/3 Volt
230/3 Volt
TRB
400/3 Volt
TRB
230/3 Volt
Wash Pump
Boiler Resistance