5.3.5 Burner

Unscrew the screws (pos. 26 fig. 2) fixing the burner to the combus-
tion chamber, unscrew the nut injector-holder (pos. 29 fig. 2), pull
down the burner (pos. 31 fig. 2) for pull off from the injector-holder,
pull off and put in a new piece in the reverse order. After the
replacement check the seal using a leack detector spray.

After any maintenance or repair work, replace the con-
trol panel and the lower panel.

After replacing gas input components, check operation
again and test for leakage.

6 - INSTRUCTIONS FOR USE

6.1 Safety, cleaning and repair rules

• This appliance is used for the preparation of meals at industri-
al level. Usage and cleaning can be carried only by expert per-
sonnel. Maintenance and repair can be carried out only by
skilled technical personnel.

• These indications must be communicated to all those con-
cerned during internal training.

• Attention! This appliance must be constantly watched over
when being used!

• Grease and overheated oil can catch fire. Use this appliance
only under constant control. Never use water to put out
grease or oil! 

• Do not leave the burners running.

• Parts of the appliance and attachments exposed to food
must be cleaned with detergents and rinsed thoroughly with
potable water.

• Do not clean the appliance using water jets or steam,
whether direct or pressurized!

• If the room is being cleaned with water/steam jets or high-pres-
sure equipment, it is necessary to switch off the appliance first!

• Before starting to clean the appliance, disconnect from the
mains.

• Do not use inflammable liquid to clean the appliance.

• Repairs may be carried out only by skilled personnel.

• During repairs, the appliance must undergo voltage
omnipolar insulation (local switch, i.e. safety load cut-off
switch).

• Noise emission values of the appliance in operation are below
70dB (A). This value is compulsory according to certain national

safety standards.

WARNING

Attention! 

The manufacturer declines all responsibility concern-

ing mistakes included in these instructions due to translating or
printing errors: the manufacturer also reserves the right to
change the product as he see fits, though without changing its
essential features. The manufacturer declines all responsibility for
any non-compliance with the provisions contained in this manu-
al.

6.2 Start-up

Before using the appliance for the first time, thorou-
ghly clean the tank with lukewarm water and deter-

gent, using a soft cloth to eliminate all trace of the
rust-proofing applied in the workshop. Dry with a
clean cloth.

Check if the water discharge is closed.

Fill the tank with oil up to the level marked.

6.2.1 Lighting pilot burner

Press the knob (pos. 5 fig. 1) and turn to the left as far as

.

Keep the knob pressed down while repeatedly pressing the piezo
ignition button (pos. 6 fig. 1) until the pilot flame catches, you can
see through aperture on the control panel. Keep the knob pressed
down for another 15-20 seconds: if the pilot flame goes out after
the knob is released, start again.

Содержание ADN 625

Страница 1: ...0805_GB_42 GAS FRYERS Instructions for installation use e maintenance ADN 625 ADN 626 04 2008 ...

Страница 2: ...0805_GB_42 GAS FRYERS 2 12 04 2008 CHARACTERISTICS Supplied by Date Customer Service FAX e mail ...

Страница 3: ...aining 7 5 1 10 Conversion and adjustment 7 5 1 11 Replacement of burner injector 8 5 1 12 Replacement of burner pilot injector 8 5 2 Maintenance 8 5 3 Replacing parts 8 5 3 1 Gas valve 8 5 3 2 Safety termostat 8 5 3 3 Thermocouple 8 5 3 4 Plug 8 5 3 5 Burner 9 6 Instructions for use 9 6 1 Safety cleaning and repair rules 9 6 2 Start up 9 6 2 1 Lighting pilot burner 9 6 2 2 Lighting the main burne...

Страница 4: ...5_GB_42 GAS FRYERS 4 12 04 2008 683 545 Data plate 150 55 678 60 700 Gas 1 2 45 310 400 34 Gas 1 2 700 Data plate 400 800 Data plate 700 34 Gas 1 2 710 45 Gas 1 2 800 ADN 626 ADN 625 45 34 34 45 1 DIAGRAM ...

Страница 5: ...kg h Nominal thermal power Minimal thermal capacity Nominal thermal power Minimal thermal capacity G20 G30 G31 20 mbar 28 37 mbar II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 1 2 0 730 0 540 2 x 145 2 x 95 Adjustable 20 1 2 1 460 1 080 4 x 145 4 x 95 Adjustable 2 x 20 Model ADN 625 14 6 9 ADN 626 28 6 9 6 9 TABLE 1 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 2...

Страница 6: ...tion chamber and flues are made of electrogalvanised steel sheeting The fryers are fitted with a safety thermostat should the temperatu re of the oil exceed the safety limit the gas is automatically cut off The temperature is set through a thermostat which controls the ignition and extinguishing of the burners 4 3 Assembly 4 3 1 Installation premises The appliance must be installed in a well venti...

Страница 7: ...l h or litre minute l min The following formula is used to calculate the value of E It is important measure the power when the appliance is in standby status The calorific power value can be requested from the local gas company The nominal power and the minimum power with respect to the nominal pressure are obtained by consulting the table for the adjustment of the gas passage table 1 WARNING Ther...

Страница 8: ...bustion safety Check functioning of the appliance as described in paragraph 5 1 6 Operation control 5 3 Replacing parts All parts must be replaced by authorized technicians only To replace the following parts first remove all the control knobs and control panel after loosening the fixing screws then extract the ignition wire 5 3 1 Gas valve Loosen the fitting of the pipe pos 3 16 17 and 21 fig 1 o...

Страница 9: ...am jets or high pres sure equipment it is necessary to switch off the appliance first Before starting to clean the appliance disconnect from the mains Do not use inflammable liquid to clean the appliance Repairs may be carried out only by skilled personnel During repairs the appliance must undergo voltage omnipolar insulation local switch i e safety load cut off switch Noise emission values of the...

Страница 10: ...n When cleaning carefully avoid washing the appliance with direct water jets or high pressure water Cleaning must be performed when the appliance is cold Thorough daily cleaning of the appliance after disconnecting it will keep it in perfect working order and make it last longer All steel parts should be cleaned with water and a detergent using a damp cloth do not use abrasive substances or corrod...

Страница 11: ...st due to rubbing Newly formed rust spots can be removed with slightly abrasive liquid soaps or fine grained sand paper Larger rust spots can be removed with 2 3 of hot oxalic acid solution If these cleaning products do not do the job a nitric acid 10 treatment is required Attention These treatments can be carried out only by expert personnel according to current regulations 6 6 3 The 2002 96 EC W...

Страница 12: ... PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Отзывы: