0805_GB_42
- GAS FRYERS
04/2008
5
· 12
2 - CHARACTERISTICS OF THE APPLIANCES
3 - TECHNICAL DATA
These appliances are used for professional purposes. Installation,
repair and use must be carried out by expert personnel.
These instructions for installation are for our gas fryers set up for
the category in the table 1 on pag. 5. The data plate is located on
the appliance, see diagram. Beware of inexpert handling.
Model
ADN 625
ADN 626
Description
Gas fryer - 1 vessel
Gas fryer - 2 vessels
N˚ Tank
1
2
Capacity
10 l
10 l + 10 l
Dimensions in mm. (LxDxH)
400 x 700 x 900
800 x 700 x 900
N.
51BS2548
51BS2548
Primary air distance “A” mm
Methane gas G20
Liquid gas G30/G31
Category
Construction type
Air necessary for combustion
Nominal thermal power
Minimum thermal power
Overall thermal power (gas)
Connection pressure
Methane gas 2H
Liquid gas 3+
Gas connection values
Methane gas 2H
Liquid gas 3+
Nozzles Ø 1/100 mm
Main burner
G20
G30/G31
(HuB = 9.45 kWh/m
3
) in m
3
/h
(HuB = 12.87 kWh/kg) in kg/h
Nominal thermal power
Minimal thermal capacity
Nominal thermal power
Minimal thermal capacity
G20
G30/G31
20 mbar
28/37 mbar
II2H3+
A
m
3
/h
kW
kW
No. of nozzles pilot burner
G20
G30/G31
1
2
0.730
0.540
2 x 145
-
2 x 95
-
Adjustable
20
1
2
1.460
1.080
4 x 145
-
4 x 95
-
Adjustable
2 x 20
Model
ADN 625
14
6.9
-
ADN 626
28
6.9 + 6.9
-
TABLE 1
0051
TIPO/TYPE
CAT/KAT
GAS/GAZ
G30
G31
G20
G25
II2H3B/P
P mbar
30
30
20
-
II2H3+
P mbar
30
37
20
-
-
II2H3+
P mbar
28
37
20
-
25
II2L3B/P
P mbar
30
30
II2ELL3B/P
P mbar
50
50
20
20
II2E+3+
P mbar
28
37
20
25
II2H3B/P
P mbar
50
50
20
-
I2E
P mbar
-
-
20
-
-
-
II2H3B/P
P mbar
30
30
II2H3+
P mbar
28
37
20
-
-
-
-
-
I3B/P
P mbar
30
30
I3+
P mbar
28
37
SE
FI
DK
CZ
SK
SI
IT
CH
PT
ES
IE
GB
GR
NL
DE
FR
BE
AT
CH
LU
EE
LV
LT
EE
LV
LT
NO
MT
CY
IS
HU
CY
MOD.
MOD.
ART.
N.
N.
Qn kW
m
3
/h
MADE IN ITALY
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: - Geschuckt voor:
V AC
kW
Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
G30/G31
28/37 mbar
G20
20 mbar