background image

3

Tools needed for
installation

Parts supplied for
installation

Parts needed for
installation

• level

• gloves

• adjustable wrench that opens to

1" or 1" hex-head socket wrench

• flat-blade screwdriver

• #2 Phillips head screwdriver

• safety glasses

• tin snipes (new vent installation)

• caulking gun and compound

• putty knife

•  8" or 10" pipe wrench

• pipe-joint compound resistant 

to L.P. gas

• pliers

• knife

• 1/4" nut driver or socket wrench

4 leveling legs

Remove parts
package from dryer
drum. Check that all 4
legs were included.

Check local codes and with gas
supplier, and read electrical, gas and
venting requirements, Pages 5 - 8,
before purchasing parts.

Gas

Gas supply line must have:

• 1/8" NPT plugged tapping.

• Shutoff valve within 6 feet of

appliance is required.

Rigid gas supply line must be:

• 1/2" IPS pipe used with a

combination of pipe fittings.

• Recommended connection to

dryer:

— New, flexible metal tubing design-

certified by AGA or CSA.

— 3/8" flare x 3/8" NPT

female.

Optional connection to dryer:

Gas supply line tubing must be:

• Lengths under 20 feet can use 3/8"

approved tubing (if codes and gas
supplier permit).

• Lengths over 20 feet should use

larger tubing.

L.P. gas conversion:

Conversion must be made by a
qualified technician. 
A qualified
service technician is someone
experienced and trained in servicing
gas equipment and familiar with
necessary precautions. See gas valve
burner base for gas conversion kit part
number*.

Fire Hazard

Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to do so can result in death or
fire.

WARNING

Venting system

Four-inch heavy metal exhaust vent
and clamps must be used. Dura Safe™
vent products are recommended.

Dura Safe vent products can be
purchased from your dealer or by
calling Whirlpool Parts & Accessories 
1-800-442-9991, Mon-Fri: 8am to 9pm
(CST), Sat: 9am to 4:30pm (CST).
Visit our internet site at 
http://www.whirlpoolappliances.com/
accessories

See Page 11 for more information.

Exhaust hood

Do Not use exhaust hoods with
magnetic latches.

4"

4"

2-1/2"

Preferred           Acceptable

Mobile home installations
require:

• Mobile Home Installation Kit, Part

Number 346764*

• Metal exhaust system hardware*

Floors sloped greater than 
1 inch:

Require Extended Dryer Feet Kit, Part
No. 279810*.

*Available for purchase from your

dealer.

Содержание 8535845

Страница 1: ...complete installation as instructed could void warranty Save Installation Instructions for local inspector s use Have questions about your dryer Call your dealer or local authorized service company When you call you will need the dryer model number and serial number Both numbers are on the model serial rating plate located in the door well behind the dryer door and on front of opening Record the n...

Страница 2: ...The location must provide Protection from weather and water Do not store or use dryer where it will be exposed to water and weather Room temperature above 45 F If room temperature is below 45 F automatic cycles may not shut off Level floor Maximum slope under entire dryer should not be more than 1 inch If slope is greater than 1 inch install Extended Dryer Feet Kit Part No 279810 Clothes may not t...

Страница 3: ...can use 3 8 approved tubing if codes and gas supplier permit Lengths over 20 feet should use larger tubing L P gas conversion Conversion must be made by a qualified technician A qualified service technician is someone experienced and trained in servicing gas equipment and familiar with necessary precautions See gas valve burner base for gas conversion kit part number Fire Hazard Use a heavy metal ...

Страница 4: ...talled The minimum unobstructed air openings are required Louvered doors with equivalent air openings are acceptable Installation clearances Use recommended clearance for easier installation Dryer dimensions Dimensions shown with feet extended 1 from bottom of dryer Most installations will require at least 5 clearance behind the dryer for the dryer vent Front view 48 sq in WARNING To reduce the ri...

Страница 5: ...may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 Explosion Hazard Use a new AGA or CSA approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 13 water column Examples of a qualified person include licensed heating personnel auth...

Страница 6: ...ied by AGA or CSA be used for connecting the appliance to the rigid gas supply line The gas pipe which extends through the lower rear of the appliance has 3 8 inch male pipe thread Copies of the standards listed may be obtained from CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Optional gas line connection method When acceptable to the gas supplier and local codes 3 8 ...

Страница 7: ...cks or bushes etc If using an existing exhaust system clean lint from entire length of system and make sure exhaust hood is not plugged with lint Replace any vinyl or metallized plastic foil vent with rigid metal or flexible metal vent Use clamps to seal all joints Do Not use duct tape screws or other fastening devices that extend into the interior of the vent to secure vent Service check Back pre...

Страница 8: ... Determine vent length The maximum length of the exhaust system depends upon the type of vent rigid or flexible metal the number of elbows used 1 See the exhaust vent length chart that matches your type hood for the maximum vent lengths you can use Do not use vent runs longer than specified in exhaust vent length charts Exhaust systems longer than specified will accumulate lint creating a potentia...

Страница 9: ...rsing door swing skip ahead to Level and exhaust dryer steps Be careful not to scratch or chip paint Place a large towel or soft cloth A on top of dryer Open dryer door Remove bottom screws from cabinet side of hinges B Loosen do not remove top screws from cabinet side of hinges Lift door until top screws in cabinet are in large part of hinge slot Pull door forward off screws Set door handle side ...

Страница 10: ... with screw Insert door strike plug in original door strike hole and secure with screw Slowly close door and check that door strike aligns with door catch F If door does not close completely slide door catch left or right within slot until strike snaps into catch D Level dryer Dryer must be level to reduce noise and assure proper performance Slide dryer onto cardboard or hardboard before moving ac...

Страница 11: ... Extra long band clamp for dryer connection Swivel collar Beveled edges allow corner installations Telescoping sections Swivel collar wall connection Provides 2 1 2 clearance between dryer and wall Great for closet installations 0 18 18 29 or 29 50 periscopes include one male snap lock fitting one extra long draw band collar and one clamp 21 2 2 1 2 Periscopes For Offset Outlets Tight Installation...

Страница 12: ...g plate Shut off electrical supply to dryer Unplug power supply cord and tape it securely to dryer Disconnect bracket from wall and reinstall in new home Not used on all models Tape lint collector lid to cabinet Tape top to cabinet Shut off gas supply valve in the gas supply line Disconnect gas fittings from dryer and cap gas supply line Tape end of dryer gas pipe Tape door to front panel Turn lev...

Страница 13: ...la garantía Conserve las instrucciones de instalación para uso del inspector de instalaciones eléctricas de su localidad Tiene preguntas sobre su secadora Llame a su distribuidor o a la compañía de servicios autorizada de su localidad Cuando llame necesitará el número del modelo y el número de serie de la secadora Ambos números están en la placa de modelo serie la cual se encuentra en la cavidad d...

Страница 14: ...mperatura es inferior a los 7 C 45 F los ciclos automáticos podrían no detenerse Piso nivelado La inclinación máxima debajo de toda la secadora no debe ser mayor de 2 5 cm 1 pulgada Si la inclinación es mayor de 2 5 cm 1 pulgada instale el Conjunto de Extensión de Patas para Secadora Parte No 279810 Si la secadora no está nivelada la ropa podría no girar debidamente y los ciclos de detección autom...

Страница 15: ...es se pueden utilizar tubos de 0 95 cm 3 8 de pulg si lo permiten los códigos y la compañía de gas Para longitudes mayores de 6 1 m 20 pies se deben utilizar tubos más largos Conversión a gas licuado propano líquido L P La conversión la debe hacer un técnico calificado Un técnico de servicio calificado es una persona con experiencia y que ha recibido la debida capacitación en mantenimiento y repar...

Страница 16: ...talen al lado de la secadora Espacios para la instalación Utilice los espacios recomendados para facilitar la instalación Recomendados mínimos Parte Parte Parte posterior Costados superior delantera Empotrada 12 7 cm 0 cm 2 5 cm 0 cm 45 cm 38 1 cm 5 pulg 0 pulg 1 pulg 0 pulg 18 pulg 15 pulg Closet 12 7 cm 0 cm 2 5 cm 0 cm 45 cm 38 1 cm 2 5 cm 2 5 cm Armario 5 pulg 0 pulg 1 pulg 0 pulg 18 pulg 15 p...

Страница 17: ...TENCIA La conexión indebida del conductor a tierra del equipo puede producir riesgo de choque eléctrico Verifique con un electricista calificado o técnico de servicio si tiene dudas sobre si la secadora ha sido debidamente puesta a tierra No modifique el enchufe provisto con la secadora Si no calza en el tomacorriente haga que un electricista calificado instale un tomacorriente adecuado Se pueden ...

Страница 18: ...ódigo Nacional de Gas Combustible ANSI Z223 última edición llave de cierre en posición abierta a la secadora línea rígida de suministro de gas Método recomendado para la conexión de la línea de gas Si los códigos locales lo permiten se recomienda usar tubos metálicos flexibles nuevos con diseño certificado por la A G A o CSA para conectar el electrodoméstico a la línea rígida de suministro de gas ...

Страница 19: ... Si utiliza un sistema de salida de aire existente limpie las pelusas a lo largo de todo el sistema de salida de aire y asegúrese de que la campana exterior de salida de aire no esté tapada con pelusas Reemplace cualquier conducto de salida de aire de vinilo o de lámina plástica metalizada con un conducto de metal rígido o flexible Utilice abrazaderas para conductos para sellar todas las juntas No...

Страница 20: ...ea empotrada closet armario en la página 4 Determine la longitud del conducto La longitud máxima del sistema de salida de aire depende de el tipo de conducto utilizado metal rígido o flexible el número de codos utilizados 1 Vea la tabla de longitudes de conductos de salida de aire que corresponda a su tipo de campana para determinar las longitudes máximas de conductos que puede utilizar No utilice...

Страница 21: ...rario a las manecillas del reloj para asegurarse de que quitó todas las cintas Limpie el tambor con un paño húmedo para eliminar el polvo C Para invertir el sentido de la apertura de la puerta Disponible únicamente en los modelos de puerta vertical lateral superancha y puerta vertical lateral grande Si no está invirtiendo el sentido de la apertura de la puerta pase a las etapas de Nivelación y sal...

Страница 22: ...a de la puerta interior NO trate de separar los paneles con un cuchillo NO jale el sello de la puerta ni los pestillos plásticos de la puerta Gire y vuelva a fijar el panel de la puerta exterior al panel de la puerta interior de manera que la manija quede en el lado donde se quitaron las bisagras Tenga cuidado de mantener el espaciador de cartón centrado entre la puerta interior y la exterior Fije...

Страница 23: ...archa la secadora Después de cinco minutos abra la puerta de la secadora Debe sentir calor dentro de la secadora Si el quemador no se incendió y usted no siente calor dentro de la secadora apague la secadora durante 5 minutos Luego verifique que todos los controles estén en la posición de ON encendido que el botón de start puesta en marcha ha sido oprimido con firmeza que esté abierta la llave de ...

Страница 24: ... para conectar a la secadora Collar giratorio Bordes biselados permiten la instalación en los rincones Secciones de extensión Conexión en la pared con collar giratorio Proporciona un espacio de 64 mm 2 1 2 pulg entre la secadora y la pared Ideales para instalaciones en un closet armario Los periscopios de 0 45 7 cm 0 18 pulg 45 7 73 7 cm 18 29 pulg o 73 7 127 cm 29 50 pulg incluyen un accesorio ma...

Отзывы: