Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved strain relief.
4. Run 3 wires, black, white and green [(or bare) 14 AWG], in
½" conduit from service panel to terminal box.
5. Use UL listed wire connectors and connect black wires
together.
6. Use UL listed wire connectors and connect white wires
together.
7. Connect ground wire to green and yellow ground wire in
terminal box using UL listed wire connectors.
8. Replace terminal box cover.
9. Check all light bulbs to make sure they are secure in their
sockets.
10. Reconnect power.
Connect Vent System
Vented Installations Only
1. Fit vent system over transition piece.
2. Seal connection with clamps.
Non-vented (recirculating) Installation
Install the deflector inside the lower vent cover with 2 - 3 x 9 mm
screws provided, using the upper screw holes.
A. Terminal box cover with knockout
A. ½" conduit
B. UL listed or CSA approved ½" strain relief
C. Black wires
D. White wires
E. Green (or bare) wire connected with
yellow-green wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
C
D
E
B
A
A. Vent system
B. Transition piece
A. Deflector
B. Upper screw holes
C. Lower vent cover
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
A
B
C