24
ProPress SP
Furnace Operations Manual
Why do you need fusing adjustments?
The
Program Level Fusing Adjust
is useful for making
minor adjustments to a single, specific Program without
altering the original Program design.
The Special Functions High/Low Fusing Adjustments
features are useful for matching the firing characteristics
of two furnaces so that they fire identically, no matter
which furnace you use.
Upon initial
Program Addition
, you will want to use
the original Program parameters as directed, until your
experience suggests a specific Program adjustment is
indicated.
14. PRESS TIME or RE-PRESS TIME is now displayed.
• PRESS TIME — Turn the
Selector Knob
to select
the amount of time required to press your ceramic
material. This function allows control of the press
time from 1—30 minutes, but does not give you
RE-PRESS time. After selecting the correct amount
of time; press the
Next
button or press the
Selector
Knob
to enter the program.
• RE-PRESS TIME — This function is password
protected and adds an additional four (4) minutes
to the selected amount when entering parameters
under Re-Press Time. To use this function, you must
have selected it in the
Special Functions
section
under
Calibration
(see page 16 of instructions). The
press rod remains extended during this period with
no pause between the amount of time selected in the
parameters and the additional four (4) minutes of the
re-press.
NOTE: THE PRESS ROD STAYS EXTENDED DURING AND
BETWEEN BOTH THE INITIAL AND RE-PRESS TIMES.
15. Cool Time
The
Cool Time
parameter specifies the length of
time the table takes to go from the full up position
to the full down position, with several intermediate
pauses along the way.
The range of values is 00 hours, 00 minutes, 00 seconds,
to a maximum of 1 hour, 39 minutes, and 00 seconds.
Rotate the
Selector Knob
to select the time value,
then push the
Selector Knob
OR press the
Next