Plug Connection Labels
LED L
PIN NUMBER
DESCRIPTION
SUGGESTION
1
Logic input 1- positive/negative
Handbrake
2
Logic input 3- positive/negative
Ext output delay timer enabled
3
Output 10- 250mA positive
4
Output 9- 250mA positive
(Siren in use)
5
Radio repeat input
6
Siren speakers live
Siren drivers positive
7
No connection
8
Logic input 2- positive/negative
Tailgate tilt switch
9
Logic input 4
Horn ring
10
Output 11- 250mA positive
11
Output 12- 250mA positive
Horn transfer positive
12
Radio repeat input
13
Siren speakers- return
Siren drivers negative
14
Ignition input- 12V DC positive
Ignition input-12V DC positive
Plug M
Plug N
Stand alone fist microphone socket
LED NUMBER
DESCRIPTION
1
Used for US specification switch panels
2
Data bus with WC lightbar LED
3
Power status LED