Mount the lightbar to the roof of the vehicle following the steps in the supplied lightbar installation guide.  

The CenCom Sapphire

™ UK is focused towards that use of any lightbar from the WeCan

®

 range. 

WeCan® Connection 

Run the green (CAN high) and grey (CAN low) WeCan® 

wires to the CenCom Sapphire

™  UK using the supplied 3 

way WeCan

® screw terminal plug supplied. Using ferrule 

crimps screw the wires into the 3 way plug using the 

following connections: 

Pin 1 = Green CAN high 
Pin 2 = Shield 
Pin3 = Grey CAN low

www.woodwayengineering.com - +44 (0) 2476 841750 
Lower Road, Barnacle, Coventry, United Kingdom, CV7 9LD

SAPPHIRE UK

CENCOM - Quick Start Guide V6.1 - 22 March 2016 

1

2

3

4

4

3

2

1

1 2 3 4 5 6 7 8

10 7 4

3

12 9 6 3

2 1

6 5 4

1 2 3

1

1

7

8

14

Mount the lightbar to the roof of the vehicle following the steps in the supplied lightbar 
Installation Guide.

The CenCom Sapphire™ UK is focused towards the use of any lightbar from the WeCAN™ 
range.

To wire the lightbar to the CenCom Sapphire™ UK, connect the lightbars attached Red power 

wire to the battery’s ‘Positive’ (+) terminal and the Black power wire to ‘Ground’ (-). Ensure that 

you install a fuse and that the correct rating for your fitted lightbar (see lightbar Installation 

instructions if unsure), is fitted in line with your 

Red 

power wire as close to the battery terminal 

as possible. If wires need to be extended, ensure that the wire used is correctly rated for the 

necessary current (recommended 125% of maximum current draw).

Run the 

Green 

(CAN High) and 

Grey

 (CAN Low) WeCan® wires to the CenCom Sapphire™

UK Using the supplied 3 Way WeCan® screw terminal plug supplied. Using Ferrule crimps 

screw the wires into the 3 Way Plug using the following connections:

Pin 1 = 

GREEN

 CAN High

Pin 2 =

SHIELD

Pin 3 =

GREY

 CAN Low

With the three wires securely fastened into the 3 Way plug, it can then be connected to plug J 
of the CenCom Sapphire™ UK by firmly mating the two connectors together.

The lightbar flash patterns can now be programmed using the supplied CenCom Sapphire™

UK programming software.

WeCan® Connection 

To wire the lightbar to the CenCom Sapphire™ UK, connect the lightbar attached red power wire to the battery’s ‘positive’ 
(+) terminal and black power wire to ‘ground’ (-). ensure that you install a fuse and that the correct rating for your fitted 
lightbar (see lightbar installation instructions if unsure), is fitted in line with your red red power wire as close to the battery 
terminal as possible. IF wires need to be extended, ensure that the wire used is correctly rated for the necessary current 
(recommended 125% of maximum current draw). 

With the three wires securely fastened into the 3 way plug, it can then be connected to plug J of the CenCom Sapphire™ 
UK by firmly mating the two connectors together. 

The lightbar flash patterns can now be programmed using the supplied CenCom Sapphire™ UK programming software. 

Содержание Woodway CenCom Sapphire

Страница 1: ...y Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com IN STALLATION GUIDE CenCom Sap...

Страница 2: ...to a vehicle it is always advisable to disconnect the battery earth The CenCom Sapphire UK has 12 Positive outlets and 8 Negative steady outlets www woodwayengineering com 44 0 2476 841750 Lower Road...

Страница 3: ...de V6 1 22 March 2016 lease Note Battery USB WC Lightbar Optional Microphone Extension Cord Shown For Reference Only N1 N2 N3 N4 N5 N6 N7 N8 4 5 6 7 8 Postive outlets 10 Amps each No Connection Negati...

Страница 4: ...way Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 4 Full Si...

Страница 5: ...CenCom 12V Input Vehicle or auxiliary battery live Fuse according to load 4 Main CenCom 12V Input Vehicle or auxiliary battery live Fuse according to load Plug B PIN NUMBER DESCRIPTION SUGGESTION 1 Ou...

Страница 6: ...tched negative 3 N3 Output switched negative 4 N4 Output switched negative Tailgate blue LEDs 5 N5 Output switched negative Tailgate red LEDs 6 N6 Output switched negative 7 N7 Output switched negativ...

Страница 7: ...yengineering com www woodwayengineering com INSTALLATION GUIDE 7 Plug J PIN NUMBER DESCRIPTION 1 WeCan high green Lightbar connection 2 WeCan shield Lightbar connection 3 WeCan low grey Lightbar conne...

Страница 8: ...ive Handbrake 2 Logic input 3 positive negative Ext output delay timer enabled 3 Output 10 250mA positive 4 Output 9 250mA positive Siren in use 5 Radio repeat input 6 Siren speakers live Siren driver...

Страница 9: ...ired with the Opti Link and Micro Link switch panels The switch panel extension cable is plugged into socket E of the CenCom Sapphire UK The tail end of the extension cable will plug into the RJ45 cou...

Страница 10: ...fuse and that the correct rating for your fitted lightbar see lightbar Installation instructions if unsure is fitted in line with your Red power wire as close to the battery terminal as possible If w...

Страница 11: ...ng com www woodwayengineering com INSTALLATION GUIDE Please note The information contained within this brochure is subject to change without prior notice Made in the UK ISO 9001 2008 ensures quality a...

Отзывы: