Whelen Engineering Company Woodway CenCom Sapphire Скачать руководство пользователя страница 2

Woodway Engineering Ltd 

Lower Road, Barnacle

Coventry, CV7 9LD

United Kingdom

Tel:  +44 (0) 24  76 841750 

Fax:  +44 (0) 24  76 621796

[email protected]

www.woodwayengineering.com

I N S T A L L A T I O N   G U I D E

2

Woodway Engineering Ltd 

Lower Road, Barnacle

Coventry, CV7 9LD

United Kingdom

Tel:  +44 (0) 24  76 841750 

Fax:  +44 (0) 24  76 621796

[email protected]

www.woodwayengineering.com

I N S T A L L A T I O N   G U I D E

2

At Woodway we strive to provide accurate up to date 

information on the products we offer.  Despite vigorous proofing 
there may be inadvertent technical inaccuracies and typography 
errors within this guide. If you spot any mistakes or errors then 
please e-mail [email protected] and 
this will be amended in future editions of this guide.   

Flasher assembly module for headlights or rear foglights
A Whelen WeCan® lightbar (Justice™ / Liberty™ / Legacy™ etc) 

is the preferred choice to use with the CenCom Sapphire UK 

for ease of fitting and functionality.   Connect your lightheads 
and your lightbar to the CenCom Sapphire™ UK as per the 
connection tables overleaf.  Using the software provided 

FOR MORE INFORMATION ON INSTALLING THE CENCOM 

SAPPHIRE UK, PLEASE VISIT THE WOODWAY ENGINEERING 

WEBSITE. 

Disclaimer

Before installing the 12 Volt CenCom Sapphire™ UK in to a 
vehicle, it is always advisable to disconnect the battery earth.
The CenCom Sapphire™ UK has 12 Positive outlets and 8 
Negative steady outlets.  

Warnings and Cautions

Options

CenCom Sapphire UK - Fuses 

At Woodway we strive to provide accurate up to date 

information on the products we offer.  Despite vigorous proofing 
there may be inadvertent technical inaccuracies and typography 
errors within this guide. If you spot any mistakes or errors then 
please e-mail [email protected] and 
this will be amended in future editions of this guide.   

Before installing the 12 Volt CenCom Sapphire™ UK in to a 
vehicle, it is always advisable to disconnect the battery earth.
The CenCom Sapphire™ UK has 12 Positive outlets and 8 
Negative steady outlets. 

www.woodwayengineering.com - +44 (0) 2476 841750 
Lower Road, Barnacle, Coventry, United Kingdom, CV7 9LD

SAPPHIRE UK

CENCOM - Quick Start Guide V6.1 - 22 March 2016 

Before installing the 12 Volt CenCom Sapphire™ UK in to a vehicle, it is always advisable to 
disconnect the battery earth.

The CenCom Sapphire™ UK has 12 Positive outlets and 8 Negative steady outlets.

Options

Flasher assembly module for headlights or rear foglights

A Whelen WeCan® lightbar (Justice™ / Liberty™ / Legacy™ etc) is the preferred choice to 
use with the CenCom Sapphire UK for ease of fitting and functionality.   Connect your 
lightheads and your lightbar to the CenCom Sapphire™ UK as per the connection tables 
overleaf.  Using the software provided configure your chosen switch panel to switch each 
outlet.

For more information on installing the CenCom Sapphire™ UK, visit the Woodway 
Engineering website.

Positive Outputs 

1 x 40 Amp circuit 
2 x 20 Amp circuits 
5 x 10 Amp circuits 
4 x 250 milliAmp circuits

Negative Outlets 

8 x 2 Amp circuits 

Amp/relay Module 

Fusing Information

LIGHTBAR

A0

2

2

TU

PT

UO

A0

2

P

NI

A

M

A0

2

A0

2

3

TU

PT

UO

A0

1

4

TU

PT

UO

A0

1

5

TU

PT

UO

A0

1

6

TU

PT

UO

A0

1

7

TU

PT

UO

A0

2

ES

UF

NEG/OL 

8

TU

PT

UO

A0

1

OUTPUT

10A

POSITION

DRY

CONTACT

POSITION

OUTPUT 1

40A

ERR

H

S

USB

L

WC POW

PA

SYSTEM

I/O

- 0

2 -

- 0

2 -

- 0

2 -

- 0

2 -

- 0

2 -

- 0

1 -

- 0

1 -

- 0

1 -

- 0

1 -

- 0

1 -

Top

View

SIREN FUSE

20A

- 20 -

Front

View

You should always remember to use 
the appropriate rated fuse for each 
individual load circuit, and never 
purposely overload any circuit as this 
may cause damage to the CenCom 
Sapphire™ UK and void the warranty.

The fuses shown are the maximum 
allowed for each circuit, and must only 
be replaced with either the same rated 
fuse or a smaller rated fuse. If a fuse 
blows, check for short circuits and the 
load requirement for that circuit. Never 
insert a larger rated fuse than that 
specified.

Quick Installation Guide

CenCom Sapphire™ UK - Fuses 

Содержание Woodway CenCom Sapphire

Страница 1: ...y Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com IN STALLATION GUIDE CenCom Sap...

Страница 2: ...to a vehicle it is always advisable to disconnect the battery earth The CenCom Sapphire UK has 12 Positive outlets and 8 Negative steady outlets www woodwayengineering com 44 0 2476 841750 Lower Road...

Страница 3: ...de V6 1 22 March 2016 lease Note Battery USB WC Lightbar Optional Microphone Extension Cord Shown For Reference Only N1 N2 N3 N4 N5 N6 N7 N8 4 5 6 7 8 Postive outlets 10 Amps each No Connection Negati...

Страница 4: ...way Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 4 Full Si...

Страница 5: ...CenCom 12V Input Vehicle or auxiliary battery live Fuse according to load 4 Main CenCom 12V Input Vehicle or auxiliary battery live Fuse according to load Plug B PIN NUMBER DESCRIPTION SUGGESTION 1 Ou...

Страница 6: ...tched negative 3 N3 Output switched negative 4 N4 Output switched negative Tailgate blue LEDs 5 N5 Output switched negative Tailgate red LEDs 6 N6 Output switched negative 7 N7 Output switched negativ...

Страница 7: ...yengineering com www woodwayengineering com INSTALLATION GUIDE 7 Plug J PIN NUMBER DESCRIPTION 1 WeCan high green Lightbar connection 2 WeCan shield Lightbar connection 3 WeCan low grey Lightbar conne...

Страница 8: ...ive Handbrake 2 Logic input 3 positive negative Ext output delay timer enabled 3 Output 10 250mA positive 4 Output 9 250mA positive Siren in use 5 Radio repeat input 6 Siren speakers live Siren driver...

Страница 9: ...ired with the Opti Link and Micro Link switch panels The switch panel extension cable is plugged into socket E of the CenCom Sapphire UK The tail end of the extension cable will plug into the RJ45 cou...

Страница 10: ...fuse and that the correct rating for your fitted lightbar see lightbar Installation instructions if unsure is fitted in line with your Red power wire as close to the battery terminal as possible If w...

Страница 11: ...ng com www woodwayengineering com INSTALLATION GUIDE Please note The information contained within this brochure is subject to change without prior notice Made in the UK ISO 9001 2008 ensures quality a...

Отзывы: